| | | YOUR PARTNER IN SENSOR TECHNOLOGY | | |
| | | |
| | | ELEKTRONIK* Ges.m.b.H. | | |
| | | |
| | | EE 2 | | |
| | | |
| | | | | | | | | | | | | | | | | EE32- | EE32- | EE32- | EE32- | EE32- | EE32- | EE32- | | | | | | | | | | | | | | Hardware Configuration Housing metal housing | M | M | M | M | M | M | M | | | | Type humidity + temperature | FT | FT | FT | FT | FT | FT | FT | | | | Model | A | B | C | D | E | I | J | | | | Filter stainless steel sintered filter PTFE filter stainless steel grid filter (up to 180°C / 356°f) | 3 5 9 | 3 5 9 | 3 5 9 | 3 5 9 | 3 5 9 | 3 5 9 | 5 9 | | | | Cable length 2m (6.6ft) (incl. probe length) 5m (16.4ft) 10m (32.8ft) 20m (65.6ft) | | | 02 05 10 20 | 02 05 10 20 | 02 05 10 20 | 02 05 10 20 | 02 05 10 20 | | | | Probe length 65mm (2.6") 200mm (7.9") 400mm (15.8") | 2 | 5 6 | 2 5 6 | 2 5 6 | 2 5 6 | 5 | 5 | | | | Pressure tight 1/2" male thread feedthrough 1/2" NPT thread | | | | | HA03 HA07 | HA03 HA07 | | | | | Display without display with display | D05 | D05 | D05 | D05 | D05 | D05 | D05 | | | | Alarm output 1) without relay with relay | SW | SW | SW | SW | SW | SW | SW | | | | 1 plug for power supply and outputs 2 plugs for power supply / outputs and RS232 | C03 C07 | C03 C07 | C03 C07 | C03 C07 | C03 C07 | C03 C07 | C03 C07 | | | | Sensing probe fixed connectable in the housing | | | P03 | P03 | P03 | P03 | P03 | | | | Coating sensor no yes | HC01 | HC01 | HC01 | HC01 | HC01 | HC01 | HC01 | | | | Supply voltage 8...35V DC / 12...30V AC integrated power supply 100...240V AC, 50/60Hz 2) | V01 | V01 | V01 | V01 | V01 | V01 | V01 | | | | | | | | | | | | | | | |
| | | |
| | | Software Configuration Physical parameters relative humidity RH [%] of outputs temperature T [°C] | | |
| | | Output 1 Output 2 | | Select according to Ordering Guide (A or B) | | |
| | | | | | | | | | | | | | | Select according to Ordering Guide (A or B) | | | | 1 2 3 5 6 | 1 2 3 5 6 | 1 2 3 5 6 | 1 2 3 5 6 | 1 2 3 5 6 | 1 2 3 5 6 | 1 2 3 5 6 | | | | E01 | E01 | E01 | E01 | E01 | E01 | E01 | | | | | | | | | | | | | | |
| | | (B) | | |
| | | |
| | | Type of output signal | | 0-1V 0-5V 0-10V 0-20mA 4-20mA | | |
| | | |
| | | |
| | | Measured value units metric / SI | | |
| | | |
| | | | | | | | | | | | non metric / US | | | | -40...60 | (T02) | -20...100 | (T14) | | | | -10...50 | (T03) | +20...120 | (T15) | | | | 0...50 | (T04) | 0...120 | (T16) | | | | 0...100 | (T05) | 0...80 | (T21) | | | | 0...60 | (T07) | ^0...80 | (T22) | | | | -30...70 | (T08) | -20...80 | (T24) | | | | -30...120 | (T09) | ^0...160 | (T33) | | | | -20...120 | (T10) | +20...180 | (T40) | | | | -40...120 | (T12) | -40...180 | (T52) | | | | | | | | | | | |
| | | |
| | | T-Scaling (in °C or °F) | | | Output T | | |
| | | Select according to Ordering Guide (Txx) Other T-scaling refer to page 134 | | |
| | | |
| | | |
| | | |
| | | |
| | | 1) Combination alarm output and plugs is not possible (with cable glands only) / combination alarm output and Integrated supply voltage is not possible 2) Integrated power supply includes 2 plugs for power supply and outputs / further plug options are not possible | | |
| | | |
| | | E EE32-MFTJ5025D05SW/AB3-T02 | | |
| | | |
| | | Hardware Configuration: Housing: metal Type: humidity + temperature Model: remote sensing probe Filter: PTFE filter Cable length: 2m (6.6ft) Probe length: 200mm (7.9") | | Software Configuration: Output 1: RH Output 2: T Output signal: 0-10V Measurand value unit: metric /SI T-Scaling: -40...60°C | | |
| | | Display: with display Alarm output: with relay Plug: cable glands Sensing probe: fixed Coating sensor: no Supply voltage: 8...35V DC/ 12...30V AC | | |
| | | |
| | | |
| | | Accessories: Pressure tight screw connections: HA011102 (1/2" ISO 012mm) HA011104 (1/2" ISO 06mm) | | |
| | | |
| | | EE 2 | | |
| | | |
| | | 8 | | |
| | | |
| | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | |