| | | YOUR PARTNER IN SENSOR TECHNOLOGY | | |
| | | |
| | | ELEKTRONIK* Ges.m.b.H. | | |
| | | |
| | | EE | | |
| | | |
| | | | | | | | | | | | | | | | | | EE33- | EE33- | EE33- | EE33- | EE33- | EE33- | EE33- | EE33- | | | | | | | | | | | | | | | Hardware Configuration Housing metal housing | M | M | M | M | M | M | M | M | | | | Type humidity + temperature | FT | FT | FT | FT | FT | FT | FT | FT | | | | Model | A | B | C | D | E | I | J | K | | | | Filter stainless steel sintered filter PTFE filter stainless steel grid filter (up to 180°C / 356°f) | 3 5 9 | 3 5 9 | 3 5 9 | 3 5 9 | 3 5 9 | 3 5 9 | 5 9 | 5 9 | | | | Cable length 2m (6.6ft) (incl. probe length) 5m (16.4ft) 10m (32.8ft) 20m (65.6ft) | | | 02 05 10 20 | 02 05 10 20 | 02 05 10 20 | 02 05 10 20 | 02 05 10 20 | 02 05 10 20 | | | | Probe length 65mm (2.6") 200mm (7.9") 400mm (15.8") | 2 | 5 6 | 2 5 6 | 2 5 6 | 2 5 6 | 5 | 5 | 2 5 6 | | | | Pressure tight 1/2" male thread feedthrough 1/2" NPT thread | | | | | HA03 HA07 | HA03 HA07 | | | | | | Interface RS232 RS485 ethernet interface 1) | N E | N E | N E | N E | N E | N E | N E | N E | | | | Display without display with display | D05 | D05 | D05 | D05 | D05 | D05 | D05 | D05 | | | | Alarm output 2) without relay with relay | SW | SW | SW | SW | SW | SW | SW | SW | | | | 1 plug for power supply and outputs 2 plugs for power supply / outputs and RS232 2 plugs for power supply / outputs and RS485 network | C03 C07 C08 | C03 C07 C08 | C03 C07 C08 | C03 C07 C08 | C03 C07 C08 | C03 C07 C08 | C03 C07 C08 | C03 C07 C08 | | | | Sensing probe fixed connectable in the housing | | | P03 | P03 | P03 | P03 | P03 | P03 | | | | Coating sensor no yes | HC01 | HC01 | HC01 | HC01 | HC01 | HC01 | HC01 | HC01 | | | | Supply voltage 8...35V DC / 12...30V AC integrated power supply 100...240V AC, 50/60Hz 3) | V01 | V01 | V01 | V01 | V01 | V01 | V01 | V01 | | | | | | | | | | | | | | | | |
| | | |
| | | Software Configuration | | |
| | | |
| | | | | | | | | | | | | | Physical | Relative humidity | RH | [%] | (A) | Output 1 | | | | parameters of | Temperature | T | [°C] | (B) | - | | | | outputs | Dew point temperature | Td | [°C] | (C) | Output 2 | | | | | Frost point temperature | Tf | [°C] | (D) | | | | | | | Tw | [°C] | (E) | | | | | | Water vapour partial pres. | e | [mbar] | (F) | | | | | | Mixture ratio | r | [g/kg] | (G) | | | | | | Absolute humidity | dv | [g/m3] | (H) | | | | | | Specific enthalphy | h | [kJ/kg] | (J) | | | | | Type of | 0-1V | | | | | | | | output signal | 0-5V 0-10V 0-20mA 4-20mA | | | | | | | | Measured value units | metric / SI non metric / US | | | | | | | | T-Scaling | -40...60 (T02) | | -20...100 | (T14) | Output T | | | | Td-Scaling | -10...50 (T03) | | +20...120 | (T15) | _ | | | | Tf-Scaling | 0...50 (T04) | | 0...120 | (T16) | Output Td | | | | Tw-Scaling | 0...100 (T05) | | 0...80 | (T21) | — | | | | (In °C or °F) | 0...60 (T07) | | -40...80 | (T22) | Output Tf | | | | | -30...70 (T08) | | -20...80 | (T24) | — | | | | | -30...120 (T09) | | -40...160 | (T33) | Output Tw | | | | | -20...120 (T10) | | +20...180 | (T40) | | | | | | -40...120 (T12) | | -40...180 | (T52) | | | | | | | | | | | | | | |
| | | Select according to Ordering Guide (A - J) | | C | | |
| | | |
| | | |
| | | D | | |
| | | Select according to Ordering Guide (A - J) | | |
| | | |
| | | |
| | | 11111111 22222222 33333333 55555555 66666666 | | |
| | | |
| | | E01 E01 E01 E01 E01 E01 E01 E01 | | |
| | | |
| | | Select according to Ordering Guide (Txx) | | |
| | | |
| | | Select according to Ordering Guide (Tdxx) | | |
| | | |
| | | Select according to Ordering Guide (Tfxx) | | |
| | | |
| | | Select according to Ordering Guide (Twxx) Other T/Td/Tf/Tw-scaling refer to page 134 | | |
| | | |
| | | |
| | | 1) Combination ethernet and alarm output is not possible / combination ethernet and integrated power supply is not possible 2) Combination alarm output and plugs is not possible (with cable glands only) / combination alarm output and integrated power supply is not possible 3) Integrated power supply includes 2 plugs for power supply and outputs / further plug options are not possible | | |
| | | |
| | | EE33-MFTD5025ND05SW/BC3-T02-Td07 | | |
| | | |
| | | Hardware Configuration: | | Software Configuration: Output 1: T Output 2: Td Output signal: 0-10V Measurand value unit: metric / SI T-Scaling: -40...60°C Td-Scaling: 0...60°C | | |
| | | |
| | | Housing: Type: Model: Filter: Cable length: | | metal humidity + temperature remote sensing probe PTFE filter 2m (6.6ft) | | Display: Alarm output: Plug: Sensing probe: Coating sensor: Supply voltage: | | with display with relay cable glands fixed no 8...35VDC/12...30V AC | | |
| | | |
| | | |
| | | Probe length: 200mm (7.9") Interface: RS485 | | |
| | | |
| | | |
| | | |
| | | 7 | | |
| | | |
| | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | |