triaxial
Model Number
3023A
3053B
3093B
3143D1
3263A2T
Sensitivity (mV/g)
Full Scale Range for +/- 5V Output (g's) Frequency Range (Hz) Weight (grams) Temperature Range (°F) Options Available
10 (-10/+15%) 500 2 to 10000
3.0 -60 to +250 3023A1 (5-40 tapped hole)
10 (+15/-10%) 500 2 to 5,000
7.2 -60 to +250 3053B1 (5mV/g), 3053B2 (10-32 mount)
100 (+15/-10%)
50
2 to 5,000 10
-60 to +250
3093B1 (10-32 mount)
100 (±5%)
50
.5 to 3,000 14
-60 to +250
3143D
(10mV/g)
100 (±10°%)
50
1.5 to 10000
5.6
-60 to +250
3263A1T
(10mV/g)
shock
ACCELEROMETERS
The measurement of high shock (up to 70,000 g's) requires an accelerometer to have the following characteristics: high natural (resonance) frequency, rugged construction, small size. These elements are com­bined in the 3200B series of internally amplified high shock accelerometers from Dytran. Series 3200B is intended for mechanical shock measurement and (by virtue to its base isolated design) for pyroshock (shock induced by an explosive device).
Six models in the 3200B series provide sensitivities of 2.0, 1.0, 0.5, 0.25, 0.1 and 0.05 mV/g, yielding full scale ranges of 2.5 Kg, 5 Kg, 10 Kg, 20 Kg, 50 Kg and 70 Kg, respectively. This series has an integral mounting stud machined as part of the housing. A top mounted 10-32 coaxial connector
provides the electrical contact.
The rugged compression design quartz sensing element in the 3200B series has a very high natural frequency (greater than 100 kHz) and is very durable. The 3200B series is electrically insulated from ground by means of an isolated base and is lightly filtered, making it suitable for pyroshock measurement to 20 kHz. A mild first order 6 dB/octave low pass filter is 5% down at 20 kHz, suppressing unwanted ringing. Standard mounting thread size for the integral mounting stud is 1/4-28; 10-32 thread (3200BT series) optional. The sensing element is a strain isolated quartz compression design.
This configuration has proven to be very reliable and will continue to perform properly even when severely overranged.
trtunuiMUNs:
Model Number
3200B
3200B2
3200B3
3200B4
3200B5
3200B6
Sensitivity (mV/g)
.05 (±10%)
.1 (±10%)
.25 (±10%)
.5 (±10%)
1.0 (±10%)
2.0 (±10%)
Full Scale Range (g's)
70,000
50,000
20,000
10,000
5,000
2,500
Frequency Range (Hz)
1 to 20,000
1 to 20,000
1 to 20,000
1 to 20,000
1 to 20,000
1 to 15,000
Weight (grams)
6
6
6
6
6
6
Temperature Range (°F)
-60 to +250
-60 to +250
-60 to +250
-60 to +250
-60 to +250
-60 to +250
LIVM
IMPEDANCE HEAD
Model 5860B
Accelerometer
100 (±10%) mV/LbF
100 (±2%) mV/g
Sensitivity
Frequency Response (+/-5%)
depends upon load
1 to 8,000
Maximum Force/Acceleration
±100 LbF
±100 g
60
Weight (grams)
DirectIndustry's Virtual Technical Library: PDF Catalogue | Technical Documentation | Brochure | Manual | Industrial directory | Specifications | Characteristics
Search Go
Contents table
page 1 p.1
page 2 p.2
page 3 p.3
page 4 p.4
page 5 p.5
page 6 p.6
page 7 p.7
page 8 p.8
page 9 p.9
page 10 p.10
page 11 p.11
page 12 p.12
page 13 p.13
page 14 p.14
page 15 p.15
page 16 p.16
page 17 p.17
page 18 p.18
page 19 p.19
page 20 p.20
page 21 p.21
page 22 p.22
page 23 p.23
page 24 p.24
page 25 p.25
page 26 p.26
page 27 p.27
page 28 p.28
page 29 p.29
page 30 p.30
page 31 p.31
page 32 p.32
page 33 p.33
page 34 p.34
page 35 p.35
page 36 p.36