LR-Cal Temperature Calibrators - DRUCK & TEMPERATUR Leitenberger - #9

/ 15


catalogue search
P. 01
P. 02
P. 03
P. 04
P. 05
P. 06
P. 07
P. 08
P. 09
P. 10
P. 11
P. 12
P. 13
P. 14
P. 15
Pages:


See other catalogues for DRUCK & TEMPERATUR Leitenberger

Text version of the page
Portable Temperature Calibrator Type Solar SOLAR Dry block calibrator +200°C to +1100°C DRUCK & TEMPERATUR Leitenberger GmbH Bahnhofstr. 33 C D-72138 Kirchentellinsfurt C Germany Tel.: +49 - 71 21 - 9 09 20 - 0 C Fax: +49 - 71 21 - 9 09 20 - 99 E-Mail: DT-Export@Leitenberger.de C http://www.druck-temperatur.de Technische Änderungen vorbehalten. Freibleibend C (Rel. 100121) • All technical modifications reserved. Without engagement Dry block Temperature Calibrator Type SOLAR & SOLAR-2I C Temperature range: +200°C to +1100°C C For mobile and stationary use C Micro processor operated C Ramp function, thermostat tests Typical applications: C Calibration and checking of all kinds of thermometer C Calibration and checking of thermostats C Computer aided calibration via RS232 interface Technical Data: Temperature range: +200°C to +1100°C Accuracy of temperature reading: ±3°C Display resolution: 0.01 / 0,1°C (switchable °C / °F) Stability of regulated temperature: ±0.3°C at 1000°C Mean heating time: 18°C per minute Mean cooling time: 6°C per minute Tubular vertical furnace with an internal quartz pipe and interchangeable equalizing block Diameter 45 mm x dept 220 mm, Equalizing block: Inconel 600, 44 mm diam. x 175 mm dept Counter-current forced air cooling system, enables to check even very short probes. Temperature uniformity: ±0.4°C horizontal and vertical RS232 interface: supplied, build-in. Ramp function Block with top insulator: 4 holes (dept 155 mm), diam. 7 - 9 - 11 - 13.5 mm, others on request Power supply: 230 VAC (optional: 115 VAC) Power consumption: 850 VA Case material: metall Dimension: 450 x 170 x 330 mm Weight: 12 kg net Note: The stated accuracy is valid at ambient temperature +10°C...+40°C and is guaranteed for 1 year. Scope of standard Supply: C Temperature Calibrator SOLAR C Electr. power cable C Fuse kit C Electr. connection cables for thermostat test C Operating manual C Certificate of calibration, traceable C Block extractor tool In addition, at type SOLAR-2I: Two Inputs for Pt100 and thermocouples, programmable C Pt 100 IEC 3-/4 wire, range -100/+700°C, accuracy ±0.3°C C Thermocouple type J, range 0-1000°C, accuracy ±1°C C Thermocouple type K/N/R/S, range 0-1300°C, accuracy ±1°C Optional Accessories: C Dry block in INCONEL 600, with top insulator, holes as per customers request C PC-Windows Software AQ2sp with RS232 cable C Probe thermocouple typ S, optional with DKD certification C Soft bag The SOLAR can operate in automatic mode connected to a PC by means of the optional AQ2sp software which enables to carry out probe calibrations and cyclical life tests; test results can be stored and printed, so they are easily traceable in compliance with ISO 9000 standards.

pageCatalog pdf di En 2012-05-22-29