Electronic Pressure Calibrator LPC 300 LPC 300
multi functional, Accuracy ±0.025% FSO
DRUCK & TEMPERATUR Leitenberger GmbH
Bahnhofstr. 33 C D-72138 Kirchentellinsfurt C Germany
Tel.: +49-7121-90920-0 C Fax: +49-7121-90920-99
E-Mail: DT-Export@Leitenberger.de C http://www.druck-temperatur.de
Technische Änderungen vorbehalten. Freibleibend C (Rel. 110330) • All technical modifications reserved. Without engagement
Technical Data:
LPC-S reference sensors, Accuracy ±0.025% FS
Pressure connection: Thread 1/2" BSP male
LPC-S high pressure reference sensors, Accuracy ±0.1% FS
Pressure connection: Thread M16x1.5 female with 60° cone
Pressure Range
[bar]
overpressure
[bar]
burst pressure
[bar]
High Pressure
Range [bar]
overpressure
[bar]
burst pressure
[bar]
0...0.25 gauge 1.6 2.4 0...1600 gauge 2300 4000
0...0.4 gauge or absolute 2 2.4 0...2500 gauge 3500 4000
0...0.6 gauge or absolute 4 4.8 0...4000 gauge 5000 8000
0...1 gauge or absolute 5 6 0...5000 gauge 6000 10000
0...1.6 gauge or absolute 10 12 0...6000 gauge 7000 11000
0...2.5 gauge or absolute 10 12 0...8000 gauge 10000 12000
0...4 gauge or absolute 17 20.5
Overpressure warning: audio visual
Temperature compensation: active, 0...50°C
Wetted parts: stainless steel, welded
Resolution: adjustable, max. 6 digits +prefix +decimal point
Measurement voltage: 0-10 V, 0-5 V, 0-1 V
Resolution: display x 0,1 mV, accuracy ±0.5 mV
Measurement current: 0-20 mA, 4-20 mA
Resolution: display x 1 ìA, accuracy ±1.6 ìA
Voltage supply: 24 VDC min. 20 mA, max. 50 mA
tolerance ±1V, switchable via user-menu.
Operation conditions: 0°C... 50°C, max. 80% r.h. non-cond.
(during battery charging: 0...45°C)
Storage: -20°C...+60°C, max. 80% r.h. non-condensing
Graphic display: high resolution TFT colour display
Storage capacity: 16 units under test, each 32 test points
RS232-Parameter: 4800, 9600 or 11200 Baud, adjustable
Battery: Lithium-Ion with intelligent charging electronics
Battery charger: 230 VAC 50/60 Hz (other on request)
Electrical connections:
charging plug 9V / 450 mA ±50 mA, with metal protection cap
PC communication: USB and RS232, with metal prot. cap
Measurement plugs:: 4 mm standard plugs for:
current measurement 0/4-20 mA
voltage measurement 0-1/5/10 V
pressure switch
Voltage supply: 24 V / 50 mA
Dimension: 12.5 x 21 x 8 cm (width x height x depth)
Weight: appr. 1.1 kg
Indicated accuracy of the LPC-S reference sensors:
calibrated at 23°C ambient temperature, in vertical position,
incl. linearity, hysteresis and repeatability.
Each LR-Cal LPC 300 unit can handle up to 10 LPC-S
reference sensors (plug & play).
0...6 gauge or absolute 35 42
0...10 gauge or absolute 35 42
0...16 gauge or absolute 80 96
0...25 gauge or absolute 50 96
0...40 gauge 80 400
0...60 gauge 120 550
0...100 gauge 200 800
0...160 gauge 320 1000
0...250 gauge 500 1200
0...400 gauge 800 1500
0...600 gauge 1200 1500
0...700 gauge 1200 1500
0...1000 gauge 1500 3000
-0.4...0 gauge 2 2.4
-0.6...0 gauge 4 4.8
-1...0 gauge 5 6
-0.25...+0.25 gauge 1.6 2.4
-0.4...+0.4 gauge 2 2.4
-0.6...+0.6 gauge 4 4.8
-1...+1.5 gauge 10 12
-1...+3 gauge 17 20.5
-1...+5 gauge 35 42
-1...+9 gauge 35 42
-1...+15 gauge 80 96
-1...+20 gauge 50 96
-1...+24 gauge 50 96
-1...+39 gauge 80 400
Optional Accessories:
• rubber protection caps for electrical measuring plugs (IP 54)
• electr. extension cable for reference sensor (order-code LPC-KABEL)
(herewith the reference sensor LPC-S can be used “outside” the LR-Cal LPC 300
unit for more flexibility). Always needed for LPC-S ranges >=1600 bar.
• carrying case with custom foams (order-code LPC300-KOFFER)
|
|