|399Hydrogen Sulfide 2 - 50 ppmOrder No.64 06 050Measuring Range: 2 to 50 ppm (20 °C, 50% r.h.) Measuring Time: approx. 20 to 200 s Rel. Standard deviation: ± 7% Ambient Operating Conditions Temperature:0 to 40 °CHumidity:1 to 40 mg/L (corresp. 2 to 80% r.h. at 40 °C) Air Pressure:700 to 1100hPa Cross Sensivity No influence at 10 ppm H2 S by≤ 50 ppm nitrogen dioxide≤ 20 ppm sulfur dioxide ≤ 200 ppm mercaptan Hydrogen Sulfide 20 - 500 ppmOrder No.64 06 150Dräger sampling tubes and systems - 20351 HMeasuring Range: 20 to 500 ppm (20 °C, 50% r.h.) Measuring Time: approx. 4 to 60 s Rel. Standard deviation: ± 13% Ambient Operating Conditions Temperature:0 to 40 °CHumidity:1 to 40 mg/L (corresp. 2 to 80% r.h. at 40 °C) Air Pressure:700 to 1100hPa Cross Sensivity No influence at 100 ppm H2 S by≤ 50 ppm nitrogen dioxide≤ 20 ppm sulfur dioxide ≤ 200 ppm mercaptan |