9044020_PI_Polytron IR N2O_en.qxd 08.11.2006 10:55 Uhr Seite 2 TECHNICAL DATA TypeTransmitter with infrared sensor technology GasesNitrous oxide (Dinitrogen monoxide, N
2 O) in ambient air Measuring range (full scale value)Configurable between 300 ppm and 1000 ppm Power supply13 to 30 V DC (nominal 24 V DC),
2 , outer diameter 6 to 12 mm Maximum cable length (at 24 V)2000 m for 3 x 1.5 mm
2 ; 1500 m for 3 x 1.0 mm
2 ; 1000 m for 3 x 0.75 mm
2 Response time t
90 at 25 °C
ORDER INFORMATION Dräger Polytron IR N 2 O, with display and keypad83 16 044 Dräger Polytron IR N 2 O NDH, w/o display and keypad, with plug connector for hand-held terminal83 16 045 Hand-held terminal83 12 580 90 44 020 | PIe | 116 | GM-PR-ED| Global Marketing ST |Printed in Germany | chlorinefree – ecological| Subject to modifications! Dräger Safety AG & Co. KGaARevalstrasse 1 23560 Luebeck, Germany Tel+49 451 882 2794 Fax+49 451 882 4991 www.draeger.com SYSTEMS CENTERS P. R. CHINA FRANCE UNITEDKINGDOM Beijing Fortune DraegerSafety Equipment Co., Ltd. Yu An Lu A 22, B Area Beijing Tianzhu Airport Industrial Zone Houshayu Shunyi District Beijing 101300 Tel+86 10 80 49 80 00 Fax+86 10 80 49 80 05 Dräger Safety France S.A.S. 3c, Route de la Fédération 67025 Strasbourg Cedex Tel+33 388 40 76 76 Fax+33 388 40 76 67 Draeger Safety UK Ltd. Blyth Riverside Business Park Blyth, Northumberland NE24 4RG Tel+44 1670 352 891 Fax+44 1670 540 033 SINGAPORE USA Draeger Safety Asia Pte. Ltd. 67, Ayer Rajah Crescent # 06 03 139950 Singapore Tel+65 68 72 92 88 Fax+65 67 73 20 33 Draeger Safety, Inc. 505 Julie Rivers, Suite 150 Sugar Land, TX 77478 Tel+1 281 498 1082 Fax+1 281 498 5190

pageCatalog pdf di En 2012-05-22-29