Dräger Chip-Measurement-System - Dräger Safety - #1

/ 4


catalogue search
Dräger Chip-Measurement-System - Dräger Safety
P. 01
Dräger Chip-Measurement-System - Dräger Safety
P. 02
Dräger Chip-Measurement-System - Dräger Safety
P. 03
Dräger Chip-Measurement-System - Dräger Safety
P. 04
Pages:
Dräger Chip-Measurement-System - Dräger Safety


See other catalogues for Dräger Safety
You may also be interested in

Goggles, Safety glasses, Camera, Respirator, Combustion analyzer


Text version of the page
DETECTION PERSONAL PROTECTION DIVING TECHNOLOGY SYSTEM TECHNOLOGY SERVICES

Dräger Chip-Measurement-System - 20351 Dräger CMS

Accurate The principle of mass current measure-ment ensures that the instrument remains unaffected by fluctuations in air pressure. Because the chips are calibrated before leaving the factory, there is no need for the user to calibrate the Dräger CMS. Any possible temperature and humidityeffects are checked during factory calibration. The analyser is explosion protected and certified in accordance withCenelec (Europe), UL (USA) and UL/CSA(Canada). In addition, the system is protected against dust and splash water inaccordance with IP 54, and is resistant to electromagnetic waves. The world's only Chip Measurement System (CMS) makes spot measurements as easy as 1, 2, 3: insert chip – start measurement – read measurement result on the LCD display. The Dräger CMS combines the advantages of the Dräger-Tubes® with those of an optoelectronic analysis system. Two components define the system: the analyserand the substance-specific chip. Dräger CMS: Simple to use The Dräger CMS is ready for use after only a brief instruction. It makes no difference which gas or vapour you wish to measure – the instrument is used in the same way every time. The operation is guided by a menu on the display and a single button/switch. The display can be backlit and is available in German, English,French or Spanish. After an automaticsystem self-test, the analyser is powered up and the measurement system is immediately ready for operation. Simply insert the chip, perform the measurement and read the measurement result displayed as a concentration on the screen. At the end of the measurement, the chip is automatically ejected from the instrument,and the analyser shuts down. An audible signal sounds after each operating step. Power is supplied by four standard andeasily replaceable batteries which are especially suited to the analyser's requirements (see technical data). The battery capacity allows for more thanseven hours of measurement and is, of course, always displayed on the screen.
ST-156-2004 ST-802-2004 Highly accurate and easy to use.
ST-1347-2004 Dräger CMS Chip: Miniaturised Dräger-Tubes.

pageCatalog pdf di En 2012-02-07-15