39
Specifi cations LIDA 489 LIDA 479
Measuring standard
Coeffi cient of linear expansion
Steel scale-tape with METALLUR graduation
Þtherm .. 10 · 10–6 K–1
Accuracy grade ± 15 ìm or ± 5 ìm after linear length-error compensation in the subsequent electronics
Measuring length ML* in mm 70 120 170 220 270 320 370 420 520 620 720 820 920 1 020
Reference marks One at midpoint of measuring length
Incremental signals » 1 VPP « TTL
Grating period 20 ìm
Integrated interpolation*
Signal period
–
20 ìm
5-fold
4 ìm
10-fold
2 ìm
50-fold
0.4 ìm
100-fold
0.2 ìm
Cutoff frequency –3dB ‡ 400 kHz –
Scanning frequency* – † 400 kHz
† 200 kHz
† 100 kHz
† 50 kHz
† 200 kHz
† 100 kHz
† 50 kHz
† 25 kHz
† 50 kHz
† 25 kHz
† 12.5 kHz
† 25 kHz
† 12.5 kHz
† 6.25 kHz
Edge separation a1) – ‡ 0.100 ìs
‡ 0.220 ìs
‡ 0.465 ìs
‡ 0.950 ìs
‡ 0.100 ìs
‡ 0.220 ìs
‡ 0.465 ìs
‡ 0.950 ìs
‡ 0.080 ìs
‡ 0.175 ìs
‡ 0.370 ìs
‡ 0.080 ìs
‡ 0.175 ìs
‡ 0.370 ìs
Traversing speed1) † 480 m/min † 480 m/min
† 240 m/min
† 120 m/min
† 60 m/min
† 240 m/min
† 120 m/min
† 60 m/min
† 30 m/min
† 60 m/min
† 30 m/min
† 15 m/min
† 30 m/min
† 15 m/min
† 7.5 m/min
Limit switches L1/L2 with two different magnets; output signals: TTL (without line driver)
Power supply
Current consumption
DC 5 V ± 5 %
< 100 mA
DC 5 V ± 5 %
< 170 mA (without load)
DC 5 V ± 5 %
< 255 mA (without load)
Electrical connection
Cable length
Cable 3 m with D-sub connector (15-pin), interface electronics for LIDA 479 in the connector
† 20 m (with HEIDENHAIN cable)
Vibration 55 to 2 000 Hz
Shock 11 ms
† 200 m/s2 (EN 60 068-2-6)
† 500 m/s2 (EN 60 068-2-27)
Operating temperature 0 °C to 50 °C
Weight Scanning head
Scale tape
Connecting cable
Connector
20 g (without connecting cable)
31 g/m
22 g/m
LIDA 489: 32 g, LIDA 479: 140 g
* Please indicate when ordering 1) At the corresponding cutoff or scanning frequency
|