catalogue search
|
You may also be interested in
3D touch probe, Control, Linear encoder, Linear length gauge, Encoder
Text version of the page
29
Specifi cations LIP 581 LIP 571
Measuring standard
Coeffi cient of linear expansion
DIADUR phase grating on glass
Þtherm .. 8 · 10–6 K–1
Accuracy grade* ± 1 ìm
Measuring length ML* in mm 70 120 170 220 270 320 370 420 470 520 570 620 670
720 770 820 870 920 970 1 020 1 240 1 440
Reference marks* LIP 5x1 R
LIP 5x1 C
One at midpoint of measuring length
Distance-coded
Incremental signals » 1 VPP « TTL
Grating period 8 ìm
Integrated interpolation*
Signal period
–
4 ìm
5-fold
0.8 ìm
10-fold
0.4 ìm
Cutoff frequency –3dB ‡ 300 kHz –
Scanning frequency*
Edge separation a
– † 200 kHz
‡ 0.220 ìs
† 100 kHz
‡ 0.465 ìs
† 50 kHz
‡ 0.950 ìs
† 100 kHz
‡ 0.220 ìs
† 50 kHz
‡ 0.465 ìs
† 25 kHz
‡ 0.950 ìs
Traversing speed † 72 m/min † 48 m/min † 24 m/min † 12 m/min † 24 m/min † 12 m/min † 6 m/min
Power supply
Current consumption
DC 5 V ± 5 %
< 175 mA
DC 5 V ± 5 %
< 175 mA (without load)
Electrical connection*
Cable length
Cable 0.5 m, 1 m, 2 m or 3 m with D-sub connector (15-pin), interface electronics in the connector
† 30 m (with HEIDENHAIN cable)
Vibration 55 to 2 000 Hz
Shock 11 ms
† 200 m/s2 (EN 60 068-2-6)
† 500 m/s2 (EN 60 068-2-27)
Operating temperature 0 °C to 50 °C
Weight Scanning head
Scale
Connecting cable
Connector
25 g (without connecting cable)
7.5 g + 0.25 g/mm measuring length
38 g/m
140 g
* Please select when ordering
|