Catalog excerpts
Centrale wentylacyjno-klimatyzacyjne EDURO LJeHTpa/lbHbie CMCTeMbl BeHTM/lfll^MM H KOHflMUKOHMpOBaHMfl EDURO
Open the catalog to page 1DOSPEL - leader of ventilation DOSPEL - lider wentylacji / DOSPEL - yikflep BeHTM/iflujiM DOSPEL Sp. z o.o. is one of the largest producers of ventilation and air-conditioning equipment and systems. DOSPEL Professional, which belongs to the DOSPEL Group, specializes in production of industrial air handling systems. With over 30 years of experience, highly qualified engineering staff and the highest quality of the products on offer, DOSPEL Professional is a solid and reliable partner. The position of the leader in the home market, as well as export of its products to more than 50 countries...
Open the catalog to page 2SPIS TRESCI / COflEP>KAHME of Dospel Professional Technology EDURO - nowy produkt Dospel Professional Technology EDURO - HOBbifi npoflyia KOMnaHMM Dospel Professional Technology 2. EDURO system capacity ranges_____________________________________________________5-7 Zakresy wydajnosci systemu EDURO Wymiary sekcji i elementow / PasMepw ceKijuM M s/ieMemoB 4. EDURO system structure Konstrukcja systemu EDURO / KoHCTpyKunn CMcreMu EDURO zespot wentylatora / y3e;i BeHTM/iflTopa nagrzewnica elektryczna / 3/ieKTpHHecKMM HarpesaTe/ib nagrzewnica wodna / BOAAHOM HarpeBaTe/ib chtodnica DX /...
Open the catalog to page 3EDURO - a new product of Dospel Professional Technology nowy produkt Dospel Professional Technology / HOBWM npoflyKT KOMnaHHH Dospel Professional Technology - EDURO is a new series of types of air-handling units based on a duct system. EDURO units are intended for use in rooms with a ventilation duct system. A sectional structure of EDURO system enables easy configuration of every unit. ■ EDURO jest nowym typoszeregiem central wentylacyjno-klimatyzacyjnych opartych na systemie kanatowym. Centrale EDURO przeznaczone sa_do pracy w pomieszczeniach gdzie system wentylacji oparty jest na...
Open the catalog to page 4EDURO 0 system capacity ranges Zakresy wydajnosci systemu EDURO 0 / npon3BOflMTe/ibHocTb cHCTeMu EDURO 0 touting / grant* / oobrpM cooling / chtodzente / ouii*flenne
Open the catalog to page 5EDURO 1 system capacity ranges Zakresy wydajnosci systemu EDURO 1 / npoM3BOflMTe/ibHocTb cHcreMM EDURO 1
Open the catalog to page 6EDURO 2 system capacity ranges Zakresy wydajnosci systemu EDURO 2 / npoM3BOflMTe/ibHocTb cHcreMM EDURO 2 ' hMtfng / grzarmt / oSorpat ^coding / chitodzerria / oxnamp/ennB
Open the catalog to page 7Dimensions of sections and elements - EDURO 0 Wymiary sekcji i elementow - EDURO 0 / Pa3Mepbi ceKi^MM M 3/ieMemoB - EDURO 0 Dimensions of the flow port - 300x500 mm Wymiary okna przeprywu wynosza. - 300x500 mm npoxoflHOro o-raepCTWfl cocTa&nmOT - 300x500 MM
Open the catalog to page 8Dimensions of sections and elements - EDURO 1 Wymiary sekcji i elementow - EDURO 1 / Pa3Mepbi ceKi^MM M 3/ieMemoB - EDURO 1 Dimensions of the flow port - 350x600 mm Wymiary okna przeptywu wynosza. - 350x600 mm flpoxoflHoro OTBepcTMfl cocTaR/ifiioT - 350x600 MM
Open the catalog to page 9Dimensions of sections and elements - EDURO 2 Wymiary sekcji i elementow - EDURO 2 / Pa3Mepbi ceKi^MM M 3/ieMemoB - EDURO 2 Dimensions of the flow port - 400x700 mm Wymiary okna przeptywu wynosza. - 400x700 mm npoxoflHoro OTBepcTMfl cocraBflfliOT - 400x700 MM
Open the catalog to page 10EDURO SYSTEM STRUCTURE - ventilation unit Zespot wentylatora/ y3e/i BemH/iflTopa ■ Centrifugal fan of high efficiency with blades bent backwards, placed directly on the engine shaft ensures optimal operation of the unit. - The unit is placed on a frame structure isolated from the casing by vibration isolators, which eliminate vibration. ■ standard EDURO units offer an option of variable fan revolutions adjustment, operated by frequency converter. Such a solution allows for fully effective use of the unit at every point of operation. ■ Wentylator promiem'owy o wysokiej sprawnosci z topatkami...
Open the catalog to page 11EDURO SYSTEM STRUCTURE - electric heater Nagrzewnica elektryczna /3/ieKTpnHecKnfi HarpeBaie/ib Entalpia i(kJ/kg) - heaters made from heating elements placed on a frame constructed from galvanized sheet; - recommended minimum airflow rate 1.5 m/s; - maximum airflow rate 4.5 m/s; - maximum temperature surrounding the heater 65 °C; - max. permissible air supply temperature 40 °C - thermostats which prevent overheating - nagrzewnice wykonane z elementow grzejnych mocowanych w ramie ■ zalecana minimalna predkosc przeptywu powietrza 1,5 m/s; - maksymalna predkosc przeptywu powietrza 4,5 m/s; -...
Open the catalog to page 12EDURO SYSTEM STRUCTURE - water heater Nagrzewnica wodna/ BOAAHOM HarpeBaTe/ib Entalpia i(kJ/kg) - exchanger made from copper pipes, on which a packet of aluminum lamellas (Cu/Al) is mounted, the entire set placed on a frame made from metal sheet; - connector pipes with an external thread on end; - supply agent: water or glycol solution; - maximum water temperature: 120 °C; - maximum water pressure: 1.6 MPa (test 2.6 Mpa); - permissible air flow rate 4.2 m/s; - wymiennik wykonany z rurek miedzianych, na ktorych osadzono pakiet lameli aluminiowych (Cu/Al), catosc umieszczona na ramie z...
Open the catalog to page 13EDURO SYSTEM STRUCTURE - DX cooler Chtodnica DX / OpeoHOBbifi oxnaflmeyib Entalpia i(kJ/kg) - exchanger made from copper pipes, on which a packet of aluminum lamellas (Cu/Al) is mounted, the entire set placed on a frame made from metal sheet; - copper connector pipes, the number of cooling sections; 1; - supplying agent: arange of cooling agents from HFC group; - permissible air flow rate 3.6 m/s; - a cooler section is equipped with a drop separator and a draining tank, which enables draining of condensate. ■ wymiennik wykonany z rurek miedzianych, na ktorych osadzono pakiet lameli...
Open the catalog to page 14EDURO SYSTEM STRUCTURE - water cooler Chtodnica wodna/ BOAAHOM oxnaflMTe/ib Entalpia i(kJ/kg) ■ exchanger made from copper pipes, on which a packet of aluminum lamellas (Cu/AI) is mounted, the entire set placed on a frame made from metal sheet; ■ connector pipes with an external thread on end; ■ supply agent: chilled water or glycol solution; ■ min. temp, of the agent: 2 °C, max. water pressure: 1.6 MPa (test 2.6 Mpa); ■ permissible air flow rate 3.6 m/s; ■ a cooler section is equipped with a drop separator and a draining tank, which enables draining of condensate; ■ wymiennik wykonany z...
Open the catalog to page 15All Dospel catalogs and technical brochures
-
Industrial Roof fans -WDeX
3 Pages
-
Industrial Roof fans - WDH
4 Pages
-
M-Box
7 Pages
-
Industrial Roof fans - WDD
8 Pages
-
K-BOX
4 Pages
-
Catalog cz61
59 Pages
-
CATALOG cz 51
48 Pages
-
ROOF FANS
19 Pages
-
DUCT-INDUSTRIAL FANS
19 Pages
-
DUCT DOMESTIC FANS
16 Pages
-
CHIMNEY CAPS
16 Pages
-
DOMESTIC FANS
28 Pages
-
Air heating units
26 Pages
-
Ventilation finishing
46 Pages
-
Product Catalog 2014
7 Pages
-
Catalogue Professional
63 Pages
Archived catalogs
-
The systems of ventilating ducts
92 Pages
-
Air heating units
40 Pages
-
Industrial ventilators
44 Pages
-
Air handling units
48 Pages