Econometer/Economizer for Ultra-Filter DF 0035 - 1100
2Pages

{{requestButtons}}

Catalog excerpts

Econometer/Economizer for Ultra-Filter DF 0035 - 1100 - 1

for Ultra-Filter™ DF 0035-1100 Econometer: Basic differential pressure monitor indicating the need to change the filter element. Economizer: Microprocessor monitoring and control indicating the most economical time to change the filter element. Econometer/Economizer Economizer installation Donaldson Ultra-FilterTM DF filters are ideal for filtration of compressed air and other gases in a wide range of applications. The “total filter” design concept behind these filters incorporates the following characteristics: • High performance • Ease of use • High efficiency • Flexibility • Compact size • Safety Additional energy cost savings can be achieve with the Ultra-Filter through the use of our Economizer microprocessor-controlled differential pressure gauge. While continuously monitoring differential pressure, the integrated microprocessor calculates the cost of element change-out relative increasing energy costs from rising pressure drop, and signals the most economic point at which to replace the filter element. AirCel™ ™ Economizer Econometer Savings by using the Economizer Operating signals can be remotely-monitored and, alternatively, the differential pressure signal can be transmitted via a standard analog interface (4-20 mA). Energy Cost Savings Through Reduction of Differential Pressure $0 $500 $1,000 $1,500 $2,000 $2,500 50 100 150 200 250 300 350 400 450 500 550 600 650 Flow Rate in scfm Annual Energy Cost Savings 1.5 psi less dp 3.0 psi less dp 4.5 psi less dp Example: 600 scfm, 3.0 psi less pressure loss, $1,452 savings per year.

Open the catalog to page 1
Econometer/Economizer for Ultra-Filter DF 0035 - 1100 - 2

Econometer/Economizer for Ultra-Filter™ DF Interfaces-Economizer +24V 1 4.20 mA 2 3 Output 4.20 mA Output for data transmission. Analog output 4-20 mA, maximum output resistance 500 Ù. +24V 1 Alarm 2 3 Alarm Output Alarm output for remote control, maximum current 0.5 A. The selection of the outputs (alarm contact or output 4-20 mA) is done via software by using the mode button and the display of the Economizer. qÉä UMMKRQPKPSPQ=Erp^F qÉä UMMKPQPKPSPV=EïáíÜáå=jÉñáÅçF c~ñ TTMKQQUKPURQ ÅçãéêÉëëÉÇ~áê]ã~áäKÇçå~äÇëçåKÅçã ïïïKÇçå~äÇëçåKÅçã açå~äÇëçå=`çãé~åóI=fåÅK `çãéêÉëëÉÇ=^áê=C=d~ë mKlK=_çñ=NOVV...

Open the catalog to page 2

All DONALDSON catalogs and technical brochures

  1. (P)-GS N

    6 Pages

  2. PLEATED BAGS

    3 Pages

  3. HPK05

    6 Pages

  4. Sensor Vents

    2 Pages

  5. Bulk hP

    4 Pages

  6. LITHOGUARD®

    2 Pages

  7. BSMmax

    2 Pages

  8. Fluid Analysis

    12 Pages

  9. DT filter

    22 Pages

  10. Strainers

    4 Pages

  11. Valves

    6 Pages

  12. Breathers

    14 Pages

  13. TT15/30/60

    2 Pages

  14. SP100/120

    4 Pages

  15. WL16

    4 Pages

  16. W613

    4 Pages

  17. FPK02

    6 Pages

  18. HPK02

    4 Pages

  19. panel filter

    1 Pages

  20. GDX

    4 Pages

  21. Exhaust Product

    186 Pages

  22. Synteq XP

    4 Pages

  23. Ultrac? AK

    2 Pages

  24. ULTRAC A

    2 Pages

  25. Rotary Valves

    10 Pages