SAFEMASTER C Multifunctional safety timer UG 6960 Flexible in function, variable in time The multifunctional safety timer UG 6960 from the SAFEMASTER C family serves the protection of staff and machinery by releasing and interrupting safety circuits. The UG 6960 combines safety time functions and safety functions in one device. Five different time functions with delay times of up to 300 minutes can be implemented, and selected flexibly and without programming via latching rotary switches. Besides safety functions such as emergency stop, protective door, non-equivalent safety sensor, two-hand or light barrier, it also allows you to connect your safety-related safety-mats and safety edges. The fine adjustment of time which is also done gradually via latching rotary switches is particularly advantageous for an optimal adjustment of the device in accordance with your application. With its construction width of 22,5 mm, the multifunctional safety timer UG 6960 supplies two N/O contacts and one semiconductor monitoring output each, delayed and undelayed. In accordance with the requirements, the number of safety contacts can be multiplied via the related extension module UG 6929 or the combined extension module UG 6912.28. Your advantages at a glance Fast and exact adjustment of different time functions Release delay Release delay can be retriggered Response delay Fleeting on make/fleeting on break Detent adjustment of delay time Suitable for several safety functions Emergency stop Safety gate Two-hand control Safety-mat / safety edge Light barrier Antivalent safety sensor
Open the catalog to page 1Multifunctional safety timer UG 6960 Technical features Complies with - Performance Level (PL) e and category 4 in accordance with EN ISO 13849-1: 2008 - Safety Integrity Claim Limit 3 (SIL CL) 3 according to IEC/EN 62061 - Safety Integrity Level (SIL) 3 according to IEC/EN 61508 and IEC/EN 61511 In accordance with EN 50156-1 for furnace installations Line-fault detection at the start button Activation via start button or automatic start With or without cross fault detection 2-channel design with digital timer Forcibly guided output contacts Output: 2 N/O contacts instant contacts and 2 N/O contacts...
Open the catalog to page 213 Pages
5 Pages
9 Pages
5 Pages
7 Pages
9 Pages
9 Pages
148 Pages
3 Pages
2 Pages
2 Pages
626 Pages
114 Pages
194 Pages
162 Pages
210 Pages
514 Pages
3 Pages
3 Pages
5 Pages
3 Pages
3 Pages
7 Pages
20 Pages
4 Pages
2 Pages
2 Pages
3 Pages
2 Pages
909 Pages
20 Pages
4 Pages
7 Pages
135 Pages