| | | Relay Carriers ET 3069 for distribution enclosures | | |
| | | |
| | | Technical Data | | |
| | | |
| | | Order reference: Outer dimensions: Enclosure material: | | (see Order reference page 2) 15,8 x 83,4 x 32,7 mm PC-GF, light grey RAL 7035 | | |
| | | |
| | | |
| | | | | | | | | | Temperature stability: | | | | | complying with UL 746 B: | 125 °C | | | | complying with Vicat ISO 306 Meth. B: | 148 °C | | | | complying with ISO 75-2 Meth. A: Meth. B: | 138 °C 144 °C | | | | Flame retardancy complying with UL 94: complying with IEC 60 707: | V-0 BH 2-30 | | | | Number of Terminals: | max. 6 | | | | | | | | | |
| | | |
| | | Terminal materail: Max. cross section for connection: Max. contact resistance to printed circuit board: Max. current carrying capacity: Wire fastening: Inner connection: Creepage current resistance: Air gap and creepage distance between input and output: Printed circuit board: Printed circuit board holder: Net weight: Accessories: KU 4089-3-4: Enclosures: | | Copper alloy, tin-plated 2 x 2,5 mm2 solid 2 x 1,5 mm2 stranded ferruled DIN 46 228-1/-2/-3/-4 | | |
| | | • Width 15,8 mm • Carriers for mounting of relais • For building-into distribution enclosures KU 4087 to KU4091 with widths 17,5 mm to 140 mm • Using for relais with: - 2 NO contacts - 1 NO contact - 1 changeover contact • Mounting with plug-in technology • Mounting surfaces for soldering of: - Electrical modules e.g. * voltage adjustment * spool switching * bus-coupling • direct electrical connection between terminal and relay contacts (no connection path via PCB) | | |
| | | |
| | | 20 mQ 10 A Captive plus-minus-terminal screws M3,5 with self raising terminal washers funktion complying with IEC 60 999-1 machine solderable Pins for PCB and solder frame for stranded | | |
| | | |
| | | CTI 175 = insulated material III a > 4 mm > 8 mm see printed circuit board designs grid lugs in carriers 30 g | | IEC 60 664-1 IEC 60 664-1 IEC 60 664-1 | | |
| | | |
| | | |
| | | |
| | | Blanking plugs for unrequired connection terminals | | |
| | | |
| | | Relay | | |
| | | |
| | | KU 4087 to KU 4091 | | |
| | | |
| | | |
| | | Plus-minus-terminal screw | | |
| | | |
| | | distribution enclosures KU 4087 bis KU 4091 | | |
| | | |
| | | Carrier | | |
| | | |
| | | Connection sheet metal Carrier mounted in distribution enclosures | | |
| | | |
| | | All specifications correspond to the technology used at time of publication. We reserve the right to make improvements and changes of a technical naturre at any time. | | |