Text version of the page
38
AMPLIFIER FOR THRU-BEAM SENSORS92CGAMP*** 92CGAMP24 or 92CGAMP230
• Amplifier for thru-beam sensor (transmitter – receiver) 92CG41**• Output: Relay or NPN
• Timer intégrée: 0 to 10 s
• Dimensions: 80 x 84 x 35 mm >
Trans/receiv thru-beam Description: >
Dimensions
• Time delay of the output signal• Output LED indicator
• Voltage LED indicator
• Sensitivity adjustment by potentiometer• Direct or inverse output• Relay or static output
• Strong housing (NORYL) Plug-in body >
35 ON time delay0-10sOFF time delay0-10sLevelSensibility adjustment: yellowOutput: redSupply: greenSwitches under cover No (1,3) broken beamNo (1,3) openbroken beamSensibility 100%Sensibility 25% 80 Applications: • Amplifier for thru-beam sensor 92CG41E/R >
42,5 75
81,5 Wiring Connections
Receiver(black cable)Transmitter(gray cable) 681011124593 7 AlarmoutputNPNSupplyOutput NPN (+)(-) Technical Information
Supply 230 VAC (± 15%) 24 VDC Consumption 2,5 VA 3 W Response time 33 ms t >
on / t >
off Switching frequency 15 Hz Relay output 10 R/250 VAC (2500 VA) Output Static 100 mA/40 VDC Timer Adjustment to 0 from 10 >
s ton >
or toff Temperature Protections degree of protection IP 20 operating -20 to 50° C storage -50 to 85° C >
To Place Order
Product Amplifier for transmitter-receiver 92CG Base for 92CGAMP24 or 230 Reference 92CGAMP230 Relay 230 VAC 92CGSOCAMP 92CGAMP24 NPN 24 VDC 11 poles circular bracket >
Non contractual document 92CGAMP_FC_FR_A Edition 01/07 Z.I. B.P. 82 - F - 76220 Gournay-en-Bray - Tél. +33.(0)2.32.89.93.10 - Fax +33.(0)2.32.89.93.11 - e-mail: dinel@dinel.com