37 THROUGH-BEAM SENSORS E/R 955 R
Sensing distance 15 m >
Technical Information
Emission Temperature External light immunity LED infra-red modulation frequency 55 Hz operating -10 à-60° C storage -20 to 80° C incandescent light 10 000 lux Protection Supply Response time voltage 18 / 240 V AC/DC consumption 2,5 VA t degree of protection IP 65 Relay output type NO relay state at rest: beam cut
at work: on demand
maximal voltage 125 VDC / 240 VAC
maximal intensity 3 A
cut power 90 W / 360 VA >
on or t >
off 100 ms switching frequency 10 Hz >
Trans/receiv thru-beam Emet/Récep and rideaux To Place Order
Product Reference Transmitter sensor M12 connector E CO 955(supplied with bracket)Receiver sensor M12 connector R CO 955 R(supplied with bracket) - lenght 2 m - straight CM 122M12 connector cable - straight CM 125 - lenght 5 m - 90° angle CM 125 C >
{
TYPE OF APPLICATIONS Example 1 Through-beam
detection on a
conveyor manufacturer. Example 2 Shiny metallic objects detection. >
Non contractual document ER 955 R_FC_FR_A Edition 01/07 Z.I. B.P. 82 - F - 76220 Gournay-en-Bray - Tél. +33.(0)2.32.89.93.10 - Fax +33.(0)2.32.89.93.11 - e-mail: dinel@dinel.com