DEWETRON Current Transducers | PM-MCTC-60/200/400/700/1000 | PM-SATURN-2000IHF/-5000I-140/-2000U/-5000U-140 | PNA-Clamp-5/-10/-20/-20-B/-150-DC/-1000 | PNA-A100-200-45/-300-80/-300-45/-300-80/-1000-120 | PNA-Flex-MINI-300-70 | PNA-Flex-300-45 - Dewetron - #1

/ 4


catalogue search
DEWETRON Current Transducers | PM-MCTC-60/200/400/700/1000 | PM-SATURN-2000IHF/-5000I-140/-2000U/-5000U-140 | PNA-Clamp-5/-10/-20/-20-B/-150-DC/-1000 | PNA-A100-200-45/-300-80/-300-45/-300-80/-1000-120 | PNA-Flex-MINI-300-70 | PNA-Flex-300-45 - Dewetron
P. 01
DEWETRON Current Transducers | PM-MCTC-60/200/400/700/1000 | PM-SATURN-2000IHF/-5000I-140/-2000U/-5000U-140 | PNA-Clamp-5/-10/-20/-20-B/-150-DC/-1000 | PNA-A100-200-45/-300-80/-300-45/-300-80/-1000-120 | PNA-Flex-MINI-300-70 | PNA-Flex-300-45 - Dewetron
P. 02
DEWETRON Current Transducers | PM-MCTC-60/200/400/700/1000 | PM-SATURN-2000IHF/-5000I-140/-2000U/-5000U-140 | PNA-Clamp-5/-10/-20/-20-B/-150-DC/-1000 | PNA-A100-200-45/-300-80/-300-45/-300-80/-1000-120 | PNA-Flex-MINI-300-70 | PNA-Flex-300-45 - Dewetron
P. 03
DEWETRON Current Transducers | PM-MCTC-60/200/400/700/1000 | PM-SATURN-2000IHF/-5000I-140/-2000U/-5000U-140 | PNA-Clamp-5/-10/-20/-20-B/-150-DC/-1000 | PNA-A100-200-45/-300-80/-300-45/-300-80/-1000-120 | PNA-Flex-MINI-300-70 | PNA-Flex-300-45 - Dewetron
P. 04
Pages:
DEWETRON Current Transducers | PM-MCTC-60/200/400/700/1000 | PM-SATURN-2000IHF/-5000I-140/-2000U/-5000U-140 | PNA-Clamp-5/-10/-20/-20-B/-150-DC/-1000 | PNA-A100-200-45/-300-80/-300-45/-300-80/-1000-120 | PNA-Flex-MINI-300-70 | PNA-Flex-300-45 - Dewetron


See other catalogues for Dewetron

Text version of the page
1 www.dewetron.com Components Signal Conditioning For Your Computer Instruments Standard Models Current Transducers High Precision Current Transducers Three to six channels Models from 200 Apk to 1000 Apk High linearity Low offset High bandwidth Low phase error Model overview 60 A - 1000 A Power supply PM-MCTS-xxx 100.000 10.000 1.000 0.100 0.010 0.001 500000 50000 5000 500 50 5 0 Amplitude-/ phase-error depending on frequency Frequency (Hz) Amplitude-error Phase-error 10.000 1.000 0.100 0.010 0.001 100 80 60 40 20 0 Amplitude-error depending on range (DC) Range (%) Amplitude-error (%) Specifications Model PM-MCTC 60 PM-MCTS 200 PM-MCTS 400 PM-MCTS 700 PM-MCTS 1000 Transducer PM-867-60I PM-867-200I PM-867-400I PM-867-700I PM-867-1000IHF Primary Current Range DC, Peak 60 A 200 A 400 A 700 A 1000 A RMS Sinus 40 A 140 A 280 A 500 A 700 A Overload Ability Normal Operation 110 % (220 Apk) 110 % (220 Apk) 110 % (440 Apk) 110 % (770 Apk) 110 % (1100 Apk) Short Time (100 mS) 500 % (1000 Apk) 500 % (1000 Apk) 500 % (2000 Apk) 500 % (3500 Apk) 500 % (5000 Apk) Bandwidth DC … 1 MHz DC … 1 MHz DC … 500 kHz DC … 250 kHz DC … 1 MHz Temperature Influence 1 ppm/K 1 ppm/K 1 ppm/K 1 ppm/K 1 ppm/K Output Ratio 200 mApk bei 60 Apk 200 mApk bei 200 Apk 200m Apk bei 400 Apk 400 mApk bei 700 Apk 1 Apk bei 1000 Apk Linearity 0.001 % 0.001 % 0.001 % 0.001 % 0.001 % Offset 0.004 % 0.004 % 0.004 % 0.004 % 0.004 % Frequency Influence 0.03 %/kHz 0.03 %/kHz 0.06 %/kHz 0.12 %/kHz 0.03 %/kHz Angular Influence 0.01° + 0.045°/kHz 0.01° + 0.045°/kHz 0.01° + 0.06°/kHz 0.01° + 0.12°/kHz 0.01° + 0.045°/kHz Shunt PM-MCTS-BR5 PM-MCTS-BR5 PM-MCTS-BR5 PM-MCTS-BR5 PM-MCTS-BR1 Optional Shunts PM-MCTS-BR1 PM-MCTS-BR2.5 PM-MCTS-BR5 1 A / 1 Ů / 1 W Shunt 800 mA / 2,5 Ů / 1 W 400 mA / 5 Ů / 1 W for MCTS 1000 Shunt for MCTS 700 Shunt for MCTS 200/400 Amplitude Accuracy 0.1 % 0.05 % 0.05 % Angular Accuracy 1° at 100 kHz 1° at 100 kHz 1° at 100 kHz Frequency Range 300 kHz / 0.5 dB 300 kHz / 0.5 dB 300 kHz / 0.5 dB Nominal Current Range Basic Three Channel System Additional Current Channel Optional Shunt 60 A (Transducer PM-867-60I) PM-MCTS-60 PM-CM-60 PM-MCTS-BR5 200 A (Transducer PM-867-200I) PM-MCTS-200 PM-CM-200 PM-MCTS-BR5 400 A (Transducer PM-867-400I) PM-MCTS-400 PM-CM-400 PM-MCTS-BR5 700 A (Transducer PM-867-700I) PM-MCTS-700 PM-CM-700 PM-MCTS-BR5 1000 A (Transducer PM-867-1000IHF) PM-MCTS-1000 PM-CM-1000 PM-MCTS-BR1 - MCTS Rack - 1 internal Power Supply - 1 Plug-On Shunt - 3 internal Power Supplies - 1 Transducer Head - 3 Transducer Heads - 1 Connection Cable - 3 Connection Cables 10 m - Power Cord

pageCatalog pdf di En 2012-05-21-27