video corpo

L 2011 The genset engine
2Pages

{{requestButtons}}

Catalog excerpts

L 2011 The genset engine - 1

12-50 kVA at 1500/1800 min-1 | rpm The engine with integrated oil cooling system. These are the characteristics of the 2011 Gen: 2, 3 and 4 cylinder naturally aspirated in-line engines. 4 cylinder model also with turbocharging. Displacement: 0.78 l/cylinder. Integrated oil-cooling (engine is delivered complete with cooler). Acoustically optimized crankcase. All service points on the same engine side. Electronic engine governor (option). Compact design and low weight. Worldwide service network with over 1,000 locations. Your benefits: u Low noise emission, cost savings as no noise attenuation measures are required. u Long service intervals: 1,000-hour oil change intervals and low fuel consumption bring savings in operating costs. u Low installation costs. u Excellent load takeover characteristics ensure prompt power supply. u Combined oil cooling and lubrication prevents corrosion and cavitation. High reliability and durability together with reduced maintenance requirement and wear parts. 2011. The Genset Engine. Dimensions and weights/integrated cooler F 2L 2011 Length: mm| inch 645 | 25.2 Width: mm| inch 588 | 22.9 Height: mm| inch 707 | 27.6 Weight: kg | lb 212 | 467 F 3L 2011 Length: mm| inch 756 | 29.5 Width: mm| inch 588 | 22.9 Height : mm| inch 701 | 27.3 Weight kg | lb 254 | 560 F 4L 2011 Length: mm| inch 868 | 33.9 Width: mm| inch 588 | 22.9 Height : mm| inch 722 | 28.2 Weight kg | lb 293 | 646 BF4L 2011 Length: mm| inch 778 | 30.3 Width: mm| inch 531 | 20.7 Height : mm| inch 704 | 27.5 Weight kg | lb 295 | 650

Open the catalog to page 1
L 2011 The genset engine - 2

u Rating table: 2011.The Genset Engine. 50 Hz Engine type F2L 2011 F3L 2011 F4L 2011 BF4L 2011 Speed min-1 | rpm 1500 1500 1500 1500 Frequency Hz 50 50 50 50 Engine/genset ratings 1) Continuous power, ICN (COP)2) kW | hp 11,4 | 15.5 18,1 | 24.6 26,2 | 35.6 34,6 | 47.1 Prime power, ICN (PRP)3) kW | hp 12,0 | 16.3 19,0 | 25.8 27,6 | 37.5 36,4 | 49.5 Limited-time running power, IFN (LTP)4) kW | hp 12,6 | 17.1 20,0 | 27.2 29,0 | 39.4 38,2 | 52.0 Typical generator power output Typical generator power output (COP)5) kVA 11,8 19,0 28,5 38,0 Typical generator power output (PRP)5) kVA 12,5 20,0 30,0...

Open the catalog to page 2

All DEUTZ catalogs and technical brochures

  1. BFM 1013

    2 Pages

  2. TCD 2012

    2 Pages

  3. TTCD 7.8 L6

    2 Pages

  4. TCD 2011

    4 Pages

  5. FL 912

    2 Pages

  6. TCD 2015M

    2 Pages

  7. D 2011L

    2 Pages

  8. D 2011Li

    2 Pages

  9. 2015M

    2 Pages

  10. TCG 2015

    2 Pages

  11. TCD 914M

    2 Pages

  12. BFM 2011

    2 Pages

  13. TCD 2013

    2 Pages

  14. BFM 1015

    2 Pages

  15. BFL 914

    4 Pages