You may also be interested in
Thermocouple, Wireless transmitter, DO meter, Multi-loop controller, Transmitter
Text version of the page
SPECÍFIC VERSIONS OF RDT-4000 SERIES RADIO-TRANSMITTERSpH REDOX LOW CONDUCTIVITY HIGH CONDUCTIVITY DISSOLVED OXYGEN ION SELECTIVERDT-4000/pH RDT-4000/ORP RDT-4000/EC RDT-4000/ECT RDT-4000/O2 RDT-4000/ESIpH sensor input0.00 to 14.00 pHPt100 ATC input 0 to 100 șCSensor test functionSensor cleaning function1 relay output ORP sensor input-2000 mV to 2000 mVPt100 input 0 to 100 șCSensor test functionSensor cleaning function1 relay output Two poles EC sensor input0 to 9.000 mS...20.00 mSPt100 ATC input 0 to 100 șCSensor test functionSensor cleaning function1 relay output Inductive EC sensor input0 to 100 mS...2000 mSPt100 ATC input 0 to 100 șCSensor test functionSensor cleaning function1 relay output Oxygen sensor input0 to 20.00 ppm and 0-100 %Pt100 ATC input 0 to 100 șCSensor test functionSensor cleaning function1 relay output Ion Selective input0.001 ppm to 9999 ppmPt100 input 0 to 100 șCSensor test functionSensor cleaning function1 relay output CHLORINE OZONE TURBIDITY SUBMERSIBLE LEVEL GAUGE PRESSURE DIFFERENTIAL PRESS.RDT-4000/CL RDT-4000/OZ RDT-4000/TB RDT-4000/TNS RDT-4000/TPR RDT-4000/TPDChlorine sensor input0 to 1.00... 10.00 ppmPt100 input 0 to 50 șCSensor test functionSensor cleaning function1 relay output Ozone sensor input0 to 2 ppm... 5.00 ppmPt100 input 0 to 50 șCSensor test functionSensor cleaning function1 relay output Turbidity probe input0 to 1000 FNU (or NTU)Pt100 input 0 to 50 șCSensor test functionSensor cleaning function1 relay output Level probe input0 to 1 m ...250 mConfigurable inputRange acc/inputFlowmeter functionAlarm function1 relay output Pressure probe input0 to 1 bar ...600 barConfigurable inputRange acc/inputSelectable unitsAlarm function1 relay output Pressure probe input-1000 to 1000 mbarConfigurable inputRange acc/inputSelectable unitsAlarm function1 relay output %RH REMOTE PROBE %RH EMBEDED PROBE %RH PSYCHROMETRIC COUNTER RPM - PERIOD WEIGHT - STRENGTHRDT-4000/HR RDT-4000/HRC RDT-4000/HPS RDT-4000/CNT RDT-4000/RPM RDT-4000/LCPHRP-150 probe input0 to 100 %RHPt100 input0 to 85 șCHold functionAlarm function1 relay output Embeded probe input0 to 100 %RHPt100 input0 to 85 șCHold functionAlarm function1 relay output HRP-150 probe input0 to 100.0 %RH0 to 35.0 g/Kg AH-40,0 to +34 șC DewPoint40 to 188 KJ/Kg EnthalpyPsychrometric Calcul.1 relay output 24 V pulse input0 to 9999 units2 Configurable inputsRanges acc/inputReset or Inhibit inputAlarm function1 relay output 24 V pulse input0 to 9999 RPM2 Configurable inputsRanges acc/inputReset or Inhibit inputAlarm function1 relay output LCP probe input0 to 1Kg ... 5000 KgTare FunctionRange acc/Load CellUnity selectableAlarm function1 relay output GAS LOW FLOW GAS FLOW LIQUID FLOW GAS SPEEDMETER LIQUID SPEEDMETER VIBRATIONRDT-4000/AFV RDT-4000/AFQ RDT-4000/LFQ RDT-4000/AFH RDT-4000/LFH RDT-4000/TGVEmbeded AFV probe0.05 NL/h ... 1000 NL/hTotaliser FunctionRanges acc/inner ductFlow parameters settingAlarm function1 relay output Embeded AFQ probe0.01 ... 34.00 Nm3/hTotaliser FunctionRanges acc/inner ductFlow parameters settingAlarm function1 relay output Embeded LFQ probe0.01 ... 150.0 m3/hTotaliser FunctionRanges acc/inner ductFlow parameters settingAlarm function1 relay output AFH insertion probe input0.001 m/s ... 30.00 m/sFlowmeter FunctionRanges acc/pipeFlow parameters settingAlarm function1 relay output LFH insertion probe input0.01 m/s ... 5.00 m/sFlowmeter FunctionRanges acc/pipeFlow parameters settingAlarm function1 relay output TGV probe input0 to 40 mm/s (5 G)Pt100 input0 to 60 șCDifferent alarms settingAlarm function1 relay output 0850 P129-0 It is reserved the right to introduce modifications without previous notice. |
|