Technical Specifications
RadiGen®400M
Performance RGN0400A
Frequency Band : 9 kHz – 400 MHz
Frequency Resolution : 1 Hz
Frequency error : +/- 100 ppm
Minimum output level : -100 dBm
Maximum output level : +13 dBm
Amplitude resolution : 0,1 dBm
Amplitude accuracy : +/- 1 dB
Maximum phase noise : -115 dBc/Hz @ 100 kHz
Modulation
Modulation types : AM and Pulse
Modulation frequency band : 1 Hz – 100 kHz
AM Modulation depth : 1% - 99%
AM accuracy 60 dB
Dimensions
Height : 100 mm (3 U)
Depth : 220 mm
Width : Takes up one free slot in a RadiCentre®
Environmental conditions
Temperature range : 100 C – 40o C
Relative humidity : 10% - 90% (non-condensing)
Power consumption
Supply voltage : 12 VDC
Power consumption : 10 W
Connectors
Output : SMA
Warranty
Warranty : 3 years
More information
For more information contact:
D.A.R.E!! Instruments at:
+31 (0)348 41 65 92 or instruments@dare.nl
Internet: www.dare.nl
DARE!!
Instruments
Dijkstra Advies, Research & EMC Instruments B.V.
Vijzelmolenlaan 7 – NL-3447 GX Woerden - The Netherlands
Tel: +31(0) 348 41 65 92, Fax: +31 (0)348 49 97 32
Internet: www.dare.nl
E-mail: instruments@dare.nl
RadiGen-UK – 2010 March - version 1.1 Specifications are subjected to changes without notice.