| | | Technical data Performance (EN 60770) | | |
| | | |
| | | | | | | | | | Accuracy (incl. nonlinearity, hysteresis and repeatability) | ±0.5% FS | | | | Thermal zero point shift | <± 0.15% FS/ 10K | | | | Thermal span shift | <±0.15% FS/ 10K | | | | Response time (10-90%) | 1 ms | | | | Overload pressure (static) | see table below | | | | Burst pressure | See table below | | | | Durability, P: 10-90% FS | >10 x106 cycles | | | | | | | | | |
| | | |
| | | Overload and burst pressure | | |
| | | |
| | | | | | | | | | | | | | | | | | | | | | | Nominal pressure [bar] | 6 | 10 | 16 | 25 | 40 | 60 | 100 | 160 | 250 | 400 | 600 | 1000* | 1600* | 2200* | | | | Overload pressure | 21 | 30 | 48 | 70 | 140 | 140 | 200 | 320 | 500 | 800 | 1400 | 2000 | 2500 | 3000 | | | | Burst pressure | 280 | 400 | 640 | 700 | 1400 | 1400 | 2000 | 1600 | 2500 | 4000 | >4000 | >4000 | >4000 | >4000 | | | | | | | | | | | | | | | | | | | | | | |
| | | |
| | | Only available with M12 x 1.5P high pressure port, type FC06. | | |
| | | |
| | | Electrical specifications | | |
| | | |
| | | | | | | | | | | | Pressure output signal (Short-circuit protected) | 0 to 5, 1 to 5 1 to 6 V | 0 to 10 V | 10 to 90% ratiometric | | | | Supply voltage [UB], polarity protected | 8 to 30 V | 12 to 30 V | 5 V ±0.5 V | | | | Supply - current consumption | 4.5 mA | 4.5 mA | 4.5 mA | | | | Output impedance | <90 Q | <90 Q | <90 Q | | | | Load [R, ] (connected to 0 V ) | RL>10 kQ | RL>10 kQ | RL>5 kQ | | | | Load [R, ] (connected to + V ) | Not possible | Not possible | RL>5 kQ | | | | | | | | | | | |
| | | |
| | | Wiring | | |
| | | |
| | | | | | | | | | | | | | | | i | V0ut1 | Customer Supply & Measure j™. | | | | V0ut2 | M | | | | | | | | | | | | I r|_2 1 | | | | | | | | | | | | | | | | | |
| | | |
| | | IC.PD.P21.H1.02 | | |
| | | 2 | | |
| | | |
| | | | | | | | | | | | | | | | | | | | | | | | |