MANUAL
11Pages

{{requestButtons}}

Catalog excerpts

MANUAL - 1

Dtferrenttal Pressure Transmitter & Pressure Transmitter Power supply: lGto45V DC (Standard a 24V X; Output signal: ito 20mA + HART or two-wire Operating temperature: -25K: to tBSt Isolating diaphragm material: SS3I-6L Hastelloy C-276, Monet or Tantalum Electromagnetic Flew Meter Nominal diameter: Pipe connection type DNIS-DNIGTOOT insertion type Liner material; PTFE jPolytelnlruarceChylene), PC [Polyo(efin)h CR (CMoroprene rubber), PUR jPotyuretrane rubber), Ff P j Fluorinated ethylerve propylene^ or on request. Electrode material: Hastelloy C Hasleltoy Tlr Ta Operating pressure; Pipe connection type ^4.0MPa, Insertion type l.Q'25MPa Operating temperature; AtfC to+lSfft according to different liner material Output signal: i to 20mA DC [Optional for 4-20mA\ DC 4 HARTr Modbus RS4S5 FtPU Model, Pile-up pulse oi Loss pulsef Power supply: ZOT ACiUnt MHz*lMir 24V Mi 10% Protection class: IPGS Explosion-proof. PCECEx d (iafi^q D CTt

Open the catalog to page 1
MANUAL - 2

Flexible Rod Target Flow Meter Output signal: a to 20mA+ HART, two-win? Compensation type: Temperature compensation. Pressure compensation

Open the catalog to page 2
MANUAL - 4

Ball Float Level Controller Accuracy; iLOmm Contactor capacrty: AC 1QW\ DC 1QQWA (Intrinsically sate only for 24V) Wetted parts material: Ilia. SSJ]?L or on request Explosion-proof; NEPsI Exia tt CT4-T6Ghr All OA 46 Gb Ball Float Level Controller Contact capacrty: AUOOVA. DC50W (Intrinsically safe only for HV) Permissible current: AC1A. DtZA Contactor type: SPDT(ane often open, one often dose} Wetted parts material: 55304, SS316L or on. request

Open the catalog to page 4
MANUAL - 5

ULG-S Double Color Quarti Glass Tube Level Gauge Measuring range (The distance between the flanges' center L|: 500mm, SOumm, llOOmm, MMmmr 1700mm or on request Operating temperature: level: -SOt to »450f1C Wetted pert: material: Carbon steel ZW, SS3CW, SS316 or on request Nominal pressure: ^E.sMPa Needle valve automatically close pressure: £0.3MPa Flushing and draining outlet: Rpl/2. Glass Plate Level Gauge Measuring range: C[oCd^anreS0£lirnrnH£D0mrnr LlOOmni, l400mmr Needle valve automatically close pressure: £0.3 MP* Wetted parts material: Carbon steer 200, SS30J, or cm request

Open the catalog to page 5
MANUAL - 6

Magnetic Ball Float Level Transmitter Nomina I d\a meter: DN|(Xlr Wetted parts material: 5S3C4. SS3-16L or on request Magnetic Float Level Transmitter Local indicator part Measuring range: Omm to WGQmm or on request Operating temperature: -4CAC to-taWe Transmitter part Explosion-proof: NEPSI Ex ia 0 CT4-T6, ExdH CT4 T6 Upper lower limit alarm: one often open, one often close Peed-based transmitter Operating temperature

Open the catalog to page 6
MANUAL - 7

Float Liquid Level Transmitter Local indicator part Meawi ng ra nge: 3Wmm to WQOmm or on feqye Transmitter part Output signal: 4 to 2DmA + HART Upper, lower limit alarm: one often open, one often dose Type Operating temperature Accuracy Rccdbascc transmitter -4£)t to +I2(ft iltimm Reed'based transmitter Magnetostrictive type transmitter tMStrt (Mate in Germany) £Q.2mm

Open the catalog to page 7
MANUAL - 8

Guided Wave Radar Level Transmitter Principle: Continuous measurement far liquid level, and interface of liquids in the process of ill industrial applications based on the principle of testing the time □f radar signals travelling along the guided wave probe. Output signal: 4 to 20mA or 4 to 20mA + HART, applicable within 3.£-20-5mA Resolution: Analog: D.OlmA, Display: 1mm Accuracy: 5mm or 0.1% FS for coaxial probe Diagnosis alarm: 3.6mA, 22mA,. Hold User interface: 3 keys, LCD or HART communication Ambient temperature: to *60<t (LCD operating temperature: -2GflC to Probe type: Coaxial for...

Open the catalog to page 8
MANUAL - 9

Displacer Level Transmitter Principle: Continuous measurements for liquid level, interface or density of liquids in the p-rocess of all industrial applications based on the proven Archimedes Buoyancy principle by deictung [lit rotary motion of torque tube. Transmitter type: L44LD (FGXBORO, Germany) Measuring range: JflOmn to3rjQGmm or on request Operating temperature: -7rjflc to+JOOt Ambient temperature i -'.fjrt: lo Cal i b rat i o n method ■ field calibration key, Cali bration softwa re with PC, or f ield communicate r (Remote control) Min, density difference: Q.OEg/cm Torque tube...

Open the catalog to page 9
MANUAL - 10

Displacer Level Transducer Output signal: iJi to 20.5mA + HART Operating temperature: -lSS'C ro+425^C Ambient temperature: ^O^C to t-SOPC Dead band: < O.OSS FS Min. density difference: O.lg/cm' Compensation: Temperature and densrty compensation. ZTD-G Smart Displacer Level Transmitter Principle; Continuous measurements for liquid level, interface or density of liquids m the process of all industrial appkatrons based on the proven Archimedes Buoyancy principle by detecting the rotary motion of torque tube. Transmitter type: DLT9000 (DDTOP; China] Output signal: IB to 20.5mA + HART Measuring...

Open the catalog to page 10
MANUAL - 11

ADD: NOL 10. HJANGHAI STREET. ZHENXING DISTRICT, DANDONG CITY, CHINA E-MAILIGp @ (Mtop.com SALES DEPARTMENT: INTERNATIONAL SALES DEPARTMENT:^ 0415 6227343 AFTER SALES SERVICE TEL>&6 0415 6225866