HFD30 - Daitron Inc - #1

/ 2


catalogue search
HFD30 - Daitron Inc
P. 01
HFD30 - Daitron Inc
P. 02
Pages:
HFD30 - Daitron Inc


See other catalogues for Daitron Inc
You may also be interested in

DC-UPS, UPS, Converter, Power supply, Switch-mode power supply


Text version of the page
Untitled table.main {} tr.row {} td.cell {} div.block {} div.paragraph {} .font0 { font:5.00pt "Arial", sans-serif; } .font1 { font:6.00pt "Arial", sans-serif; } .font2 { font:7.00pt "Arial", sans-serif; } .font3 { font:8.00pt "Arial", sans-serif; } .font4 { font:10.00pt "Arial", sans-serif; } .font5 { font:11.00pt "Arial", sans-serif; } .font6 { font:13.00pt "Arial", sans-serif; } .font7 { font:14.00pt "Arial", sans-serif; } .font8 { font:23.00pt "Arial", sans-serif; } .font9 { font:10.00pt "Georgia", serif; } Switching Power Supply HFD30 _ ■ Features ■ Topology :Compound résonance System ■ Super-low noise , low ripple voltage and low leakage current , ■ Low electric magnetic field strength , low conduction noise * about 20dB margin against class B ■ Worldwide input , RoHS regulation ■ Halogen free(printed circuit board) ■ Vinyl chloride free ■ Meet Safety Standard ■ EMC standard compliance ■ Model configuration HFD 30 - 12 Series NameOutput Power Output Voltage <Daitron Specification ~-— Type HFD30-12_ HFD30-15_ | Input Voltage Rating 100-240Vac (range : 85~264Vac) Input Frequency Rating 50/60Hz (range : 47Hz~63Hz) Input Input Current (Note 1) ACIN 100V/200V 0.9A/0.45A (IO=100%) Inrush Current (Note 1) ACIN 100V/200V 20A/40A (Ta=25 cold start) Efficiency (Note1) ACIN 100V/200V 76%/78% 76%/78% Leakage Current 0.04mA typ(100Vac,60Hz) / 0.10mA typ(240Vac,60Hz) Output Voltage +12Vdc -12Vdc +15Vdc -15Vdc Output Current 2.2A 0.3A 1.5A 0.5A Output Max Output Power 30.0W 30.0W | Line regulation 48mV max 60mV max 60mV max 60mV max Load regulation 100mV max 150mV max 120mV max 150mV max Ripple Noise (Note 2) 3mV typ 2mV typ 3mV typ 2mV typ Current limit (Note 3) Short-circuited on output terminals protection (shut down output) Accessory Function Over-voltage protection (Note 3) Rated output voltage x115% and over (shut down output) Remote Sensing Non Remote Control Available Operate Indication LED lighting Cooling System Free air convection cooling Mechanical Size (WxHxD) 84x30x161.5mm (without Terminal stand) Weight 460g Input and Output Terminal/Signal Terminal Screw Terminal Operating Temperature -10 ~ +60 (with output) 1 Operating Humidity 30%RH ~ 90%RH (non condensing) Environment Storage Temperature -20 ~ +85 Storage Humidity 10%RH ~ 95%RH (non condensing) Vibration 19.6m/s2 10~55Hz 1min X,Y,Z each an hour Impact 196.1m/s2 11ms X,Y,Z each one time Dielectric Withstand INPUT - FG : 2kVac(20mA) 1min Isolation Voltage INPUT - OUTPUT : 3kVac(20mA) 1min OUTPUT -FG : 500Vac(20mA) 1min Insulation Resistance INPUT-FG , INPUT-OUTPUT , OUTPUT-FG Over 100 M Q at 500Vdc Electrostatic discharge EN61000-4-2 Electromagnetic Fields Immunity EN61000-4-3 Electrical Fast Transient EN61000-4-4 Surge immunity EN61000-4-5 Conducted emission LISN EN61000-4-6 Safety Power Supply Harmonic Immunity Test EN61000-4-8 Standard Voltage Dip,Short Interruption, Voltage Fluctuation Immunity EN61000-4-11 Conduction Noise EN55022-B , FCC-B , VCCI-B Safety Standard UL60950-1 ,CSA-C22.2 NO.60950-1, EN60950-1 Electrical Appliance and Material Safety Law UL File No E237238 CE mark^ng Low Voltage Directive (Note 1) Conditions : Ta = 25 It is a TYP value at the time of the maximum output power. °C (Note2) JEITA measuring method It is based on a 100MHz oscilloscope. (Conditions : Ta = 25 Vin = 100Vac It is a TYP value at the time of a rated output) (Note 3) The input is intercepted, and it returns the input the re-turning on after a few minutes. Note : Derating is required by operating temperature. Follow the overload and specification in manual to avoid the damage of Power Supply.

pageCatalog pdf di En 2012-05-20-19