You may also be interested in
DC-UPS, UPS, Converter, Power supply, Switch-mode power supply
Text version of the page
Untitled
table.main {}
tr.row {}
td.cell {}
div.block {}
div.paragraph {}
.font0 { font:5.00pt "Arial", sans-serif; }
.font1 { font:6.00pt "Arial", sans-serif; }
.font2 { font:7.00pt "Arial", sans-serif; }
.font3 { font:8.00pt "Arial", sans-serif; }
.font4 { font:10.00pt "Arial", sans-serif; }
.font5 { font:11.00pt "Arial", sans-serif; }
.font6 { font:13.00pt "Arial", sans-serif; }
.font7 { font:14.00pt "Arial", sans-serif; }
.font8 { font:23.00pt "Arial", sans-serif; }
.font9 { font:10.00pt "Georgia", serif; }
Switching Power Supply
HFD30 _
■ Features
■ Topology :Compound résonance System
■ Super-low noise , low ripple voltage and low leakage current ,
■ Low electric magnetic field strength , low conduction noise * about 20dB margin against class B
■ Worldwide input , RoHS regulation
■ Halogen free(printed circuit board)
■ Vinyl chloride free
■ Meet Safety Standard
■ EMC standard compliance
■ Model configuration HFD 30 - 12
Series NameOutput Power Output Voltage
<Daitron
Specification
~-—
Type
HFD30-12_
HFD30-15_ |
Input Voltage
Rating 100-240Vac (range : 85~264Vac)
Input Frequency
Rating 50/60Hz (range : 47Hz~63Hz)
Input
Input Current (Note 1)
ACIN 100V/200V
0.9A/0.45A (IO=100%)
Inrush Current (Note 1)
ACIN 100V/200V
20A/40A (Ta=25 cold start)
Efficiency (Note1)
ACIN 100V/200V
76%/78%
76%/78%
Leakage Current
0.04mA typ(100Vac,60Hz)
/ 0.10mA typ(240Vac,60Hz)
Output Voltage
+12Vdc
-12Vdc
+15Vdc
-15Vdc
Output Current
2.2A
0.3A
1.5A
0.5A
Output
Max Output Power
30.0W
30.0W |
Line regulation
48mV max
60mV max
60mV max
60mV max
Load regulation
100mV max
150mV max
120mV max
150mV max
Ripple Noise
(Note 2)
3mV typ
2mV typ
3mV typ
2mV typ
Current limit
(Note 3)
Short-circuited on output terminals protection (shut down output)
Accessory Function
Over-voltage protection
(Note 3)
Rated output voltage x115% and over (shut down output)
Remote Sensing
Non
Remote Control
Available
Operate Indication
LED lighting
Cooling System
Free air convection cooling
Mechanical
Size (WxHxD)
84x30x161.5mm (without Terminal stand)
Weight
460g
Input and Output Terminal/Signal Terminal
Screw Terminal
Operating Temperature
-10 ~ +60
(with output)
1
Operating Humidity
30%RH ~ 90%RH (non condensing)
Environment
Storage Temperature
-20 ~ +85
Storage Humidity
10%RH ~ 95%RH (non condensing)
Vibration
19.6m/s2 10~55Hz 1min X,Y,Z each an hour
Impact
196.1m/s2 11ms X,Y,Z each one time
Dielectric Withstand
INPUT - FG : 2kVac(20mA) 1min
Isolation Voltage
INPUT - OUTPUT : 3kVac(20mA) 1min
OUTPUT -FG : 500Vac(20mA) 1min
Insulation Resistance
INPUT-FG , INPUT-OUTPUT , OUTPUT-FG
Over 100 M Q at 500Vdc
Electrostatic discharge
EN61000-4-2
Electromagnetic Fields Immunity
EN61000-4-3
Electrical Fast Transient
EN61000-4-4
Surge immunity
EN61000-4-5
Conducted emission LISN
EN61000-4-6
Safety
Power Supply Harmonic Immunity Test
EN61000-4-8
Standard
Voltage Dip,Short Interruption, Voltage Fluctuation Immunity
EN61000-4-11
Conduction Noise
EN55022-B , FCC-B , VCCI-B
Safety Standard
UL60950-1 ,CSA-C22.2 NO.60950-1, EN60950-1 Electrical Appliance and Material Safety Law
UL File No
E237238
CE mark^ng
Low Voltage Directive
(Note 1) Conditions : Ta = 25 It is a TYP value at the time of the maximum output power. °C
(Note2) JEITA measuring method It is based on a 100MHz oscilloscope. (Conditions : Ta = 25 Vin = 100Vac It is a TYP value at the time of a rated output)
(Note 3) The input is intercepted, and it returns the input the re-turning on after a few minutes.
Note : Derating is required by operating temperature. Follow the overload and specification in manual to avoid the damage of Power Supply.
|
|