Compact Analytical Balances HR-AZ/HR-A Series HR-250AZ/ HR-250A 252 g x 0.1 mg HR-251AZ/ HR-251A 62 g/252 g × 0.1 mg/1 mg HR-150AZ/ HR-150A 152 g x 0.1 mg HR-100AZ/ HR-100A 102 g x 0.1 mg HR-250AZ imate Value! Ult HR-250A ISO 9000 CERTIFIED ...Clearly a Better Value http://www.aandd.jp

 Open the catalogue to page 1

Finally, Globally Proven Precision at a Fair Price What do you expect most from a precision analytical balance? If you are like us, you will agree that accuracy and reliability come before anything else. The HR-AZ/HR-A series of compact analytical balances, behind their simple design, utilize proven A&D sensor technology that delivers superior performance to all users who wish to do superior work. Optimizing value, the HR-AZ/HR-A series realizes the following three savings: 1. Saving “Time” Fast Stabilization in 2 Seconds Our widely-recognized Compact Super Hybrid Sensor (C-SHS) technology i now...

 Open the catalogue to page 2

Large Removable Breeze Break with Antistatic Coating The breeze break is treated with an antistatic agent to ensure stable weighing. It also offers a large working space and can be detached for better portability and easy cleaning of the balance. Removable Breeze Break Clear, Reverse Backlit LCD Front-Mounted Spirit Level The contrast of the black and white display provides excellent readability even in a dimly-lit area. The spirit level is easily visible when adjusting the leveling feet of the balance for accurate weighing. Twelve Weighing Units You can easily choose from gram, milligram, ounce,...

 Open the catalogue to page 3

Specifications Models HR-250AZ Weighing capacity 252 g Minimum weighing value 0.1 mg Repeatability (standard deviation) HR-251AZ HR-150AZ HR-100AZ HR-250A 152 g 102 g 252 g 62 g / 252 g iv 0.1 mg / 1 mg 0.1 mg / 0.5 mg 0.1 mg ±0.3 mg / ±1 mg ±0.2 mg 200 to 252 g: 0.2 mg ±0.3 mg / ±1 mg ±0.3 mg ±0.2 mg Stabilization time (when set to FAST under a good environment) Approx. 2 seconds Sensitivity drift v ±2 ppm/°C (10 to 30 °C/50 to 86 °F) Internal calibration Yes Clock and calendar function Yes No No 5 to 40 °C (41 to 104 °F), 85% RH or less (no condensation) Operating environment 5 times/second...