P5000
High Pressure Sensor
Description
Features
Good EMC Performance All welded Stainless Steel Construction Isolated Stainless Steel Diaphragm Low Power Consumption High Vibration Tolerance Fault Tolerant Circuitry
Temperature Compensated
Amplified Linear Output
The P5000 series of pressure sensors utilizes thin film strain gauge sensing technology that is paired with our custom ASIC to produce a stable, accurate output.
The rugged stainless steel
construction allows the sensor to
be installed in harsh operating
environments.
Using a 5 Vdc input, the sensors provide a 0.5 to 4.5 Vdc linear amplified output proportional to pressure. Internal temperature
compensation provides an
accurate, easy-to-use device.
Specifically designed for high volume, OEM applications, the P5000's stainless steel sense element allows for extremely wide liquid or gaseous media compatibility.
Technical Specifications
Applications
Industrial Hydraulics
Refrigeration Compressors
Standard Full Scale
Pressure Ranges
0-100, 0-150, 0-200, 0-250, 0-300, 0-400, and 0-500 BAR
Injection Molding
Fuel Cells Transportation
CNG - Compressed Natural Gas LNG - Liquefied Natural Gas
Vehicle Stability Control
(VSC) Systems
Gasoline & Diesel Direct Injection Power Steering Mobile A/C Systems (R744/C02)
Note: Performance Specifications with 5v ± 0.002 Vdc Supply at 25°C
Service Life:
Vibration:
Shock:
Response Time:
Housing Material:
Weight:
Electrical Termination: Pressure Connection: Recommended Interface Impedance:
10 Million Full Pressure Cycles Min. 25 g's Random 50 g's Minimum >3mSec
Stainless Steel (316L/17-4 PH) 40 grams Max.
Built-in Mating Connector, TYCO Quadlock See "How to Order"
25k Ohm Min. Resistance between Transducer Output and Ground in Parallel with 0.2 mF Max. Capacitance 16 Vdc 5 Vdc
Pressure Ranges: Proof Pressure: Burst Pressure: Supply Voltage: Supply Current: Output Voltage (Ratiometric):
Voltage Ratiometricity:
Total Error Band (TEB): Output Impedance:
Operating Temperature: Storage Temperature:
0-100 through 0-500 BAR
2X
3X
5.0 ± 0.25 Vdc 5 mA (Max)
0.5 to 4.5 Vdc
0.5% of Span
±1% FS between -25°C and +100°C, 3% FS from -40°C to +140°C < 100 Ohms Max. -40°C to +140°C -55°C to +150°C
Over-Voltage Protection: Reverse Polarity Protection: