P356
Low Pressure Differential/Gage Transducers
Description
Features
• Superior Long Term Stability
• Excellent Repeatability/Hysteresis
• EMI/RFI Protection
• Low Power Consumption
• Linear Amplified Output
• Temperature Compensated Over a
Large Range
. Over-Voltage, Reverse Polarity & Short
Circuit Protection . Ten Million Cycle Life Expectancy . Outstanding Shock & Vibration Performance . Main Port Suitable for Dry & Wet Media
The model P356 is based
on Kavlico's field-proven ceramic
capacitive technology. The
brass housing surrounds a
low-pressure transducer
designed specifically for
pressures between 0.5 PSI
and 5 PSI. It is available
in both gage (with a protective
cap) and differential versions.
The P356 package has a built-in Metri-Pack 150, electrical connector, a y4-18 NPT main pressure fitting and a V4" hose fitting for the differential reference port
(low side).
Applications
Standard Full Scale
Pressure Ranges
0-.5, 1.0 , 1.3 and 5.0 PSIG, PSID
- 0.5 to + 0.5, -1 to +1
PSIG, PSID
Water Tower Levels Waste Water Systems Crankcase Over-Pressure Plant Automation Equipment Pneumatic Controls Filter Monitoring Leak Detection
Technical Specifications
Note: Performance Specifications with 5v ± 0.002 Vdc supply at 25°C
0 - 0.5 PSI through 0 - 5.0 PSI
Gage or Differential
2x Hi-side (1 PSI low-side)
3x Hi-side (3 PSI low-side)
5.00 ±0.25 Vdc
3 mA (Max)
15ms Max to 63% of F.S. Pressure with Step Change on Input.
0.50 ±0.08 Vdc
4.50 ±0.08 Vdc 1.5% of F.S.
< 2.0% of Span (-20°C to + 100°C)
< 100 O
-30°C to + 100°C
(Seal Material Dependent)
Pressure Ranges:
Proof Pressure: Burst Pressure: Supply Voltage: Supply Current:
Response Time: Output Voltage:
Zero/Null Pressure:
Full Pressure: Ratiometricity: Total Error Band: Output Impedance:
Operating Temperature:
Storage Temperature: Service Life:
Vibration: Shock: Stability: Humidity:
Weight:
Electrical Termination: Preferred Mounting Position:
Pressure Connection: Recommended Interface Impedance:
Over-Voltage Protection: Reverse Polarity Protection:
Material-Main housing:
-40°C to + 125°C
10 Million Full Pressure Cycles
10G's P-P Sinusoidal, 10 Hz - 2 kHz
75 G's Vi Sine Wave
±0.5% of Full Span over 1-Year
99% Non Condensing
128 grams Max
Metri-Pack 150, Electrical Connector
None
V4-18 NPT and V Tube (low-side)
Min. Load 25 kO 16 Vdc -5 Vdc CA360 Brass
Model No. P356 © 2007 Kavlico. All rights reserved. November 2007