|
|
See other catalogues for Crison Instruments
You may also be interested in
Text version of the page
| | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | 20 GLP 22 (continuation) | | | | | | | | | | Technical specifications | | | | | | Operation The GLP 22 software has been designed so that the operator can usethis high-performance pH-meter by following on-screen instructions, using a simple keypad and practically without having to read the instructions manual. | | | | | | | | | | | | | | | | | Measuring ranges | pH -2 ...16,mV± 2000, °C -20 ...150 and relative mV, mol /I10-5 ...10"1 (or ppm org/l). | | | | Resolution | Standard, 0.01 pH, 1 mV,0.1°C. Selectable, 0.1, 0.001 pH, 0.1 mV. | | | | Measuring error (± 1 digit) | s 0.003 phU0.2 mV.sO.2 °C. | | | | Reproducibility (± 1 digit) | ±0.01 pH,±1 mV,±0.1°C. ±0.001 pH,±0.1 mV,±0.1 °C. | | | | Input impedance | >1012Ohm(n). | | | | Autom. temperature compensation | With Pt 1000ATC probe or entering data using the keypad. | | | | pH calibration | ln2or3 points, validity 0h...7 days. Special calibration, 1 selectable point between 0...14 pH. Recalibration warning with option of forced recalibration. Rejection of defective electrodes. Accepted electrode values: -slope 50... 65 mV/pH,at25°C. - sensitivity 86... 110%. - asymmetry potential ± 40 mV. | | | | Autom. buffer recognition | Technical pH 2.00,4.01, 7.00, 9.21,10.90, (at25°C). NIST pH 1.679,4.0061, 6.865, 9.180,10.254, (at 25°C). | | | | History of pH electrode | Last 10 calibrations. No. of measurements, etc. | | | | Measuring programs | A fixed one and four user-modifiable ones. | | | | Data logger | Storage capacity: 447 readings. Alphanumeric and graphical reports | | | | Display | Alphanumeric backlit crystal display. 4 lines of 20 characters. | | | | Languages | English, Spanish, french, italian. | | | | Power up diagnostic | RAM, EPROM, EEPROM memories, display and keypad. | | | | Inputs and outputs | Measuring electrode, BNC connector. Reference electrode, banana 0 4. ATC, Pt 1000 type, telephone or banana connector 0 4. Interface for standard PC keyboard. Interface RS 232 C, bidirectional. Polarising current, 10uA (i.e. for Karl Fischer). Analog outlet, electrode potential follower. Control for CRISON stirrer: On/Off and speed. | | | | Power supply | 12VDC/275 mA external power supply | | | | Electrical safety | Meets EC, EN 61010. | | | | EMC (Electromagnetic compatibility) | MeetsEC, EN 50081-1 andEN 50082-1. | | | | Permitted ambient conditions | Operatingtemperature 5...40°C Storage and transport temperature -15... 65 °C. < 80 % relative humidity, non condensing. | | | | Enclosure | Casing material, high density polyurethane. | | | | Physical parameters | Weight 1.580 g, dimensions 180x215x 130 mm. | | | | | | | | | | | | | pH | | | | | | | | | | | | | | Communications software GLP-PC Software forWindows, making capture and availability of data on PC easier. The GLP 22 can be operated from a PC thanks to its two-way RS 232 C interface. | | | | | | | | | | * pH 7,01 .... v. I. . - I - r . .' - . J. -» . - - -~f - - r - ~ f "~" " '. ' ~ ~* ~~ -~ ' ~ - ' — -V-/' - - - | | | | | | | | | | j1 ■ | | | | | | | | | | PC display example | | | | | | | | | | | | | | Specifications suject to change without notice Ordering information | | | | | | | | | | | | | | | | | Code | | | | | 22 00 | GLP 22 with accessories, without electrode | | | | 22 01 | GLP 22 with accessories and electrode 52 01, with integrated ATC | | | | 22 02 | GLP 22 with accessories and electrode 52 02 | | | | 22 03 | GLP 22 with accessories, electrode 52 02 and ATC 55 31 | | | | 22 04 | GLP 22 with accessories, electrode 52 01 and magneticstirrer | | | | | | | | | | | | | Certificates The GLP 22 is supplied with the specifications Certificate and the EC Declaration of Conformity as per directive EMC 89/336/EC. For further information, please see page 132. | | | | | | | | | | PLUG-IN POWER SUPPLY: The instrument is supplied with a 230 VAC plug-in power supply. For 115 VAC, please specify when ordering. SENSORS: Electrodes. Pleaseseepages36... ATC Temperature probe, Pleaseseepage44 ACCESSORIES: flexible arm, electrode cable and 250 ml bottles of pH 4 and pH 7 buffer and electrolyte. OPTIONAL ACCESSORIES: See page 61 | | | | | | | | | | | | | | Laboratory Catalogue 2004 1st Edition | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | |
|