11
Display examples
Simultaneous measurement of pH and temperature.
Keypad
The whole range of functions can be accessed using only 4 keys, both In pH-meter and thermometer modes.
Technical specifications
Operation
The PH25 software Is similar to that of all other CRISON portables, and has been designed to make the use of this new range of Instruments as easy as possible.
pH
mil
pH IU.JC
EIE-
mV measurement
Measuring ranges
pH-meter. -2.00...16.00 pH, ± 1500 mV and -20...150 °C thermometer, -200...600°C.
Resolution
pH-meter, 0.01pH,1mV,0.1°C. thermometer, 0.1 °C,-99.9... 199.9
1°C, for the rest of the range.
Measuring error (± 1 digit)
pH-meter, s 0.01 pH, s 1mV, s 0.2°C. thermometer, £0.2°C,-99.9... 199.9
s 1°C, for the rest of the range.
Reproducibility (± 1 digit)
pH-meter, ± 0.01 pH, ±1 mV,± 0.1°C. thermometer, ±0.1°C,-99.9 ... 199.9
± 1°C, for the rest of the range.
Input impedance
> 1012 Ohm (Q) The change from high to low impedance is made int the electrode connector.
Autom. temperature compensation
By entering the temperature value using the keypad. Using a temperature sensor.
pH calibration
With 1,2or3 buffers chosen from the following values: pH 2.00,4.01, 7.00,9.21 and 10.90 (at 25°C). Selection of theoretical calibration.
Display
Liquid crystal with pictograms.
Keypad
Membrane, 4 keys. Guaranteed for up to 6 million strokes per key.
Material: PET with protective treatment
Sensors connector
MP-5, five-contact multipin. IP 67 protection.
Power supply
Two 1.5V, type AA batteries, autonomy of over 1000 h.
Electrical safety
EN61010-1.EN61010-1/A2.
EMC (Electromagnetic compatibility)
Meets EC, EN 61326, EN 61326/A1.
Degree of protection
IP 65.
Permitted ambient conditions
Operating temperature 0... 50°C.
Storage and transport temperature -15... 65°C.
< 80 % relative humidity, non condensing.
Enclosure
Casing material: ABS.
Physical parameters
Weight 200 g, dimensions 160x 75x 50 mm.
Instrument In calibration mode with one, two or three buffers.
inn
pH
I.UU
ffl
CAL.
Icon blinking
Measuring as a thermometer
Low battery warning
Icon blinking
Specifications suject to change without notice
Ordering information
Code Description
25 00 PH25 without accessories
25 01 PH 25 with accessories, without electrode
25 02 PH 25 with accessories and carry case, without electrode
ACCESSORIES: Bottles of 125 ml of pH 4, pH 7and pH 9 buffer solutions and small flasksfor calibration. ELECTRODES: The electrode must be requested separately for all versions of the PH25. (See Pages 32-33). TEMPERATURE PROBES: Described on pages 44 and 98.
Laboratory Catalogue 2004 1st Edition