You may also be interested in
Switch, Control panel, Monitoring system, Controller module, Control
Text version of the page
paralleling all-in-one All-in-one genset control and paralleling unit with integrated PLC Compact "all-in-one" module I/O flexibility Internal logic sequences, programmable by equations and the Easy PLC software New multi-function graphic display Isolated serial ports: RS485, 2 CAN bus, SD card reader, Ethernet J1939 communications with electronic engines Fully compatible with all speed governors and AVRs The GENSYS 2.0 is a control unit designed for generator electrical panels. This "all-in-one" unit combines all necessary functions: Three phases mains failure Engine start/stop and protections Alternator control and protections Mechanical parameters display Electrical parameters display Genset synchronization Load sharing and kW control Load sharing and kVAR control GENSYS 2.0 is configurable via its front panel or via a PC with CRE Config software. It has an embedded Web site which is password protected. The GENSYS 2.0 controller has analog load sharing lines and is compatible with most of the types of analog load sharing modules. www.crelechnology.com PROGRAMMING BY EQUATIONS The GENSYS 2.0 controller is a real PLC unit where equations and sequences can be programmed directly by the user with text editor software or Easy PLC software. INPUTS / OUTPUTS WITH NO LIMIT The number of inputs/outputs that can be added is one of the most important on the market. Extension modules (DIN rail mounting) can be added on the CAN bus. This extends a large number and a large diversity of inputs/outputs up to 128 digital inputs, 64 digital outputs, 44 analog inputs, 32 analog outputs and CANopen standard module. MINIMUM OPTIONS The GENSYS 2.0 is offered with a minimum of options to fit all types of application without expensive add-on packages. The standard GENSYS 2.0 unit is recommended for all types of power plant, from 1 to 32 generators. For specific needs, the following options are available : Mains paralleling Phase shift compensation (ie: Dyn11) External start module management ^added J L valu» EQUATIONS : Embed your knowledge! GENSYS 2.0 integrates a real PLC unit in which user equations and sequences can be written using a simple text editor or graphically designed using the Easy PLC software. INTER-UNIT ISOLATED CAN BUS The GENSYS 2.0 features an isolated CANbus dedicated to inter-module communication (dead busbar management, static paralleling, kW and kVAR load sharing...). CANbus technology provides high reliability communication while maintaining low wiring cost and complexity.
|
|