| | | CompactPCI | | |
| | | |
| | | CompactPCI Technical Data | | |
| | | |
| | | | | | | | | | Working voltage CPH 38 | | | | Contacts36, 37 and 38 | lOOOVr.m.s. | | | | Contacts 1 through 20 | 500Vr.m.s. | | | | Contacts 21 through 35 | 333 Vr.m.s. | | | | CPH 47 | | | | Contacts45, 46and47 | lOOOVr.m.s. | | | | Contacts 1 through 20 | 500Vr.m.s. | | | | Contacts 21 through 44 | 333 Vr.m.s. | | | | | | | | | |
| | | |
| | | | | | | | | | Mechanical Characteristics | | | | | Blind mating system | male and female connector bodies provide "lead-in" for 1.3 mm diametral misalignment | | | | | | | | | |
| | | |
| | | Polarization | | provided by connector body design | | |
| | | |
| | | |
| | | Crimp contacts | | install contact from termination side; release from mating side | | |
| | | |
| | | |
| | | Removable contact retention in connector body Size 16 contacts | | |
| | | 67 N | | |
| | | |
| | | Fixed contact retention in connector body Size 16 contacts Size 20 and 22 contacts | | |
| | | 45 N 27 N | | |
| | | |
| | | Resistance to solder heat | | 260°C for 10 seconds duration per IEC 512-6, Test 12e, 25-watt soldering iron for other application contact factory | | |
| | | |
| | | |
| | | | | | | | | | Sequential contact mating system | | | | CPH 38 | first mate contact 36 and last mate contact positions 22, 25, and 28 | | | | CPH 47 | first mate contact 45 and last mate contact position 27 | | | | Safety recessed in insulator contacts | following size 16 contacts are recessed 5mm belowthe face ofthe female insulator for safety requirements | | | | CPH 38 | contact positions 37 and 38 | | | | CPH 47 | contact positions 46 and 47 | | | | | | | | | |
| | | |
| | | Compliant terminations | | size 16, 20 and 22 contacts are available with compliant contact terminations | | |
| | | |
| | | |
| | | Printed board and panel mounting | | mounting holes provided in connector body for both printed board and panel mouting self-tapping screws are available | | |
| | | |
| | | |
| | | Mechanical operations | | 250 cycles | | |
| | | |
| | | |
| | | | | | | | | | Climatic Characteristics | | | | | Working temperature | -55°Cto+125°C | | | | Technical alterations are subjects to change without notice. | | | | | | | | | |
| | | |
| | | NEC 21 3 | | |
| | | |
| | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | |