CS & CL Continuous Duty Data
CS & CL Extended Duty Data
29
TECHNICAL DATA—115VAC AND 230VAC Models*
Torque Speed Duty VA Max Running Max Effective Peak
Output (seconds Cycle Rating Current at Full Inrush Current
(breakaway) per 90°) Load (True RMS) (=.66 x peak inrush)
rotation)
115VAC 230VAC 115VAC 230VAC 115VAC 230VAC
150 in lb 8 75% 70vA 115vA .6 amps .5 amps 1.25 amps .924 amps
300 in lb 15 75% 70vA 115vA .6 amps .5 amps 1.25 amps .924 amps
600 in lb 30 75% 70vA 115vA .6 amps .5 amps 1.25 amps .924 amps
1000 in lb 25 75% 92vA 161vA .8 amps .7 amps 1.66 amps 1.29 amps
1500 in lb 40 75% 92vA 161vA .8 amps .7 amps 1.66 amps 1.29 amps
2000 in lb 55 75% 92vA 161vA .8 amps .7 amps 1.66 amps 1.29 amps
2500 in lb 70 75% 92vA 161vA .8 amps .7 amps 1.66 amps 1.29 amps
3000 in lb 75 55% 92vA 161vA .8 amps .7 amps 1.66 amps 1.29 amps
ACTUATOR MODEL#’s/DESCRIPTION
230 VAC . . . . . . . . . . . . . . . . . . . 230 VAC MOTOR
24 VAC . . . . . . . . . . . . . . . . . . . . 24 VAC MOTOR (1) (Continuous Duty only)
12/24 VDC . . . . . . . . . . . . . . . . . 12 OR 24 VDC MOTOR (Continuous Duty only)
X. . . . . . . . . . . . . . . . . . . . . . . . . NEMA 4,4X,7, & 9
W . . . . . . . . . . . . . . . . . . . . . . . . NEMA 4 & 4X
H. . . . . . . . . . . . . . . . . . . . . . . . . TROPICAL HEATER
S2. . . . . . . . . . . . . . . . . . . . . . . . TWO AUXILIARY SWITCHES SPDT
T . . . . . . . . . . . . . . . . . . . . . . . . . HEATER AND THERMOSTAT
K. . . . . . . . . . . . . . . . . . . . . . . . . MOTOR BRAKE(2)
Z . . . . . . . . . . . . . . . . . . . . . . . . . DECLUTCHABLE HANDWHEEL OVERRIDE
(1) NOT AVAILABLE WITH CSA LISTING. CONTACT FACTORY FOR CSA
LISTING ON OPTION COMBINATIONS
(2) NOT REQUIRED ON CONTINUOUS DUTY CYCLE UNITS
CONTROL OPTIONS FOR CONTINUOUS DUTY CYCLE*
R2. . . . . . . . . SINGLE RELAY 2 WIRE CONTROL
C. . . . . . . . . . POSITIONER (SPECIFY SIGNAL)**
CL2. . . . . . . . POSITIONER WITH FAIL SAFE BACKUP FOR CS SERIES(1)
CL3. . . . . . . . POSITIONER WITH FAIL SAFE BACKUP FOR CL SERIES(1)
L2. . . . . . . . . FAIL SAFE BATTERY BACKUP FOR CS SERIES***(1)
L3. . . . . . . . . FAIL SAFE BATTERY BACKUP FOR CL SERIES***(1)
J . . . . . . . . . . SPEED CONTROL/TIMER BOARD/3 WIRE RELAY (Extended Duty only)
NOTE: NO MANUAL OVERRIDE ON FAILSAFE UNITS
*CONTACT ACTUATOR ENGINEERING FOR APPLICATIONS NOT COVERED BY
INDICATED OPTIONS
*OPTION AVAILABILITY AND PRICES ARE SUBJECT TO CHANGE WITHOUT
NOTICE
**OPTION “C” INCLUDES POSITION TRANSMITTER & CYCLE RATE
REGULATOR
***OPTION “CL2”,”CL3”,”L2”, &”L3” INCLUDE POSITION TRANSMITTER
A BOARD OPTION MUST BE SELECTED WITH CONTINUOUS DUTY CYCLE. ONLY
ONE BOARD OPTION CAN BE INSTALLED IN THE ACTUATOR.
*Notes:
1. The Current Draws stated above include all options. If the brake and/or heater & thermostat are not installed, the actual current draws will be less.
2. For Extended Duty Cycle Models, Current Draws are provided at full running torque. If the actuator encounters an overtorque condition, such as a stall condition, the
Current Draw will be vastly increased.
3. “Continuous Duty actuators contain brushless DC motors and are therefore not limited by duty cycle restraints in environments at or below 104°F; in ambient environments
above this temperature the duty cycle is de-rated to 80%.”
How To Order Examples
ACTUATOR MODEL TORQUE ENCLOSURE OPTIONS VOLTAGE
CS XXX 600 W-NEMA IV C (POSITIONER) 115VAC
CL XXX 2500 W-NEMA IV S2 (TWO SWITCHES) 230 VAC
CS & CL
Specifications
and Options
Actuators and Controls
12VDC 24VDC 24VAC 115VAC 230VAC
Torque Duty Cycle Time Current Draw Cycle Time Current Draw Cycle Time Current Draw Cycle Time Current Draw Cycle Time Current Draw
(in-lbs) Cycle (sec/90°) Amps (sec/90°) Amps (sec/90°) Amps (sec/90°) Amps (sec/90°) Amps
150 100% 11 2.2 13 1.2 8 1.8 9 0.4 9 0.4
300 100% 17 2.5 13 1.4 12 2.1 13 0.5 13 0.4
600 100% 17 2.8 13 1.7 13 2.5 14 0.6 14 0.5
1000 100% 21 4 14 2.4 15 3.5 15 0.9 15 0.6
1500 100% 40 4 24 2.4 27 3.5 29 0.9 29 0.6
2000 100% 40 4.3 33 2.4 28 3.5 29 0.9 29 0.6
2500 100% 55 3.3 40 2 38 3.1 39 0.8 39 0.6
3000 100% 60 3.7 42 2.2 40 3.5 42 0.8 43 0.6
|