Pharmaceutical
Operating Temperatures Up to 450°F (232°C)
Sanitary Flange with Nipple
T13 Terminal Head shown
Diameter "A"
3" Standard
Length
Sanitary Flange Assemblies are available in an array of termination styles, including stainless steel and FDA-approved white plastic. Nipple assemblies include a rugged 3" standard pipe nipple to extend the distance between the mounting flange and the terminal head.The 16 AMP sanitary flange, made of 316 Series stainless steel, is available in four flange sizes with two sheath diameters. Available sensors include
Thermocouple Type T (Copper/Constantan) with special limits of error or RTDs in 100, 200 or 500, 3-wire configurations with a 0.00385//°C coefficient and ±0.3° C @ 0° C tolerance. Sanitary flange assemblies provide quick mounting for sensor changeovers. The flange clamp and
industrial seal are not included, but both are available from Conax Buffalo. Dual assemblies and
closer tolerances are also available. Consult factory for details.
Progressive Description Example: SA1
Sensor Type Sheath Diameter "A" Tip Configuration Termination Style
S A 1 - T T - 3 1 6 S S 1 8 - U - T 1 3 T- S F S A - 1 0 - 4 .0 0 "
SFSA
Sanitary Flange Size
.00"
Sheath Length in Inches, 0.25" increments
TT Copper/Constantan, Special Limits of Error ERTDF43W3 100,0.00385//°C 3 wire ERTDF86W3 200,0.00385//°C 3 wire ERTDF215W3 500,0.00385//°C 3 wire
316SS18 - 0.187" Dia. 316SS25 - 0.250" Dia.
(Thermocouple only, not required for
INDUSTRIAL RTD) U - Ungrounded G - Grounded
T13 FDA,White, NEMA 4, Screw Top T13F FDA,White, NEMA 4, Flip Top T13T FDA,White, NEMA 4, Screw Top,accepts "Hockey Puck"transmitters T5SS 316 SS,NEMA 4, Screw Top,accepts "Hockey Puck"transmitters
10 = 1.5" 20 = 2.0" 25 = 2.5" 30 = 3.0"
Length required...
TM
For more information call: 1 - 8 0 0 - 2 2 3 - 2 3 8 9 · e-mail: c o n a x b u f @ c o n a x b u f fa l o . c o m · visit our website: w w w. c o n a x b u f fa l o . c o m