INDUSTRIAL RTD MINIATURE BEARING TEMPERATURE SENSORS
New Product Design
The bearings of industrial rotating equipment operate under arduous conditions often for considerable periods of time. The most reliable indicator of bearing condition is the temperature of the metal beneath the shoe. Recognition of rising temperature can provide a warning of the breakdown of the
lubricating oil film, allowing machine shutdown and maintenance to take place before catastrophic failure of the bearing and possible damage to its mounting. Conax Miniature
Bearing sensors provide a simple and cost-effective method to monitor bearing temperatures.
FEATURES
· · · · · For embedded applications in rotating machines RTDs 100 platinum, 0.00385 //°C Various styles and sizes Operating Temperature: to +250° F (+120° C)
Thermocouple assemblies also available consult factory
TYPES AND DIMENSIONS
A
B
E
SPECIFICATIONS
RTDs: 100 platinum, 0.00385 //°C; 2-, 3- and 4-wire single element configurations, Class 'B' tolerance to DIN 43760:1980 and IEC 751:1995 Silver plated, stranded copper conductors, 24 AWG, Teflon® insulated with extruded Teflon jacket overall or 24 or 26 AWG, Teflon insulated with optional stainless steel braid and extruded Teflon jacket overall. Sheath Materials: 316SST, Copper Alloy or Brass.
Se ns or
For individual tolerances consult CBT.
Sensor Type Diameter (in.) Length (in.)
A 0.275 0.250
B* 0.187 sheath 0.250 end cap 0.250
E 0.250 0.250
*Note: Springs and retaining clips are available for Type B sheaths.
Ju nc tio nT Se ns ype or Co nfi gu Le rat ad ion wi re Ty pe
Be ari ng
Mi nia tur e
Sh
Progressive Description Example:
MBS-B-CU-P1.3-X-1-24TE-36.0/1.0
X
Sheath Type Sheath Material Sensor Type Junction Type
Sh
1
Sensor Configuration Leadwire Type
Le ad wi re Le ng th
ter Ma th
ial Ty p Se ns or th ea Ty pe e
ea
/
Leadwire Length
A = 0.275" dia. x 0.250" length B = 0.187" dia. x 0.250" length E = 0.250" dia. x 0.250" length
SS = 316SS CU = Copper
CN = Copper, Nickel Plated CT = Copper, Tin Plated BR = Brass
P1.2 = RTD 2 wire P1.3 = RTD 3 wire P1.4 = RTD 4 wire
X = RTD
1 = Single Detector
24TE = 24AWG, Teflon insulated leads, Teflon jacket. 24ST = 24AWG, Teflon insulated leads, SST overbraid, with overall Teflon jacket. 26ST = 26AWG, Teflon insulated leads, SST overbraid, with overall Teflon jacket.
Length x (in.)/ Length y (in)
x = Overall length (36.0" standard) y = Length of exposed wire, including 1/2" exposed leads (1.0" total standard)
For more information call: 1-800-223-2389 · e-mail: conaxbuf@conaxbuffalo.com · visit our website: www.conaxbuffalo.com