Online Function Since the traffic on a PROFIBUS line must by no means be interrupted, active/ ongoing measuring methods on a continuously running unit are not an option for the detection of installation problems on PROFIBUS lines. In order to meet these requirements, the NetTEST II was enhanced with new and very efficient online measurement methods providing precise information about existing installation problems even on a running PROFIBUS network. The NetTEST II in this case runs in a completely passive monitoring mode and performs a detailed analysis of the data traffic as well as the physical state of the PROFIBUS line. NetTEST II comes with the following Online functionalities: Live List, measurement of the signal quality of each DP Slave, rotation time of the whole DP network, analysis of data traffic between DP Master and DP Slave, triggering upon communi- cation status changes. Simply high-tech in hand-held format! DP-Mono-Master Function Another highlight is the optional DP- Mono-Master function of NetTEST II. The I/O Data of the connected DP Slaves can be visualised and modified without the use of the provided PLC. This facilitates a most efficient control of the connected sensors/actuators. The time consuming tests of functionality by use of PLC can be omitted. Further features are the detailed display of incoming diagnosis messages and the well-aimed execution of specific PROFIBUS services.

PROFIBUS NetTEST II

PROFIBUS Analysis & Test Tool

Description

No more nerve-racking and expensive search for installation errors in PROFIBUS segments! NetTEST II represents the 2nd generation of hand-held PROFIBUS test tools developed by COMSOFT. It provides an immediate, extensive report, revealing errors of installation and professional fitting in PROFIBUS segments. NetTEST II's field of application is not restricted to diagnostics in running systems. One of the main purposes of NetTEST II is to allow the installer to check – directly after the installation – whether he has made any installation errors. Therefore, sporadic errors caused by incorrect bus physics can be excluded from the very beginning. NetTEST II gives information on: short circuit, cable rupture or broken shield, mixed up cables, wrong number of terminations, not powered termina-tions, not terminated cables, tap lines, cable length, line impedance, inhomo-geneous cables in the segment, PROFI-BUS baud rate, PROFIBUS live list, participant selective RS485 signal level, reflections with peak-peak value detection. NetTEST II is equipped with a data memory for storage of up to 20 detailed test reports in ASCII format according to the installation guideline of the PNO (PROFIBUS User Organization). If necessary, these can be printed out via a COTS PC. NetTEST II is operated via a 6 x 4 keyboard and a fully graphical 128 x 64 Pixel LCD-Display with background illumination. The user is menu-guided through the different tests. It is also possible to select a certain test directly. NetTEST II service case NetTEST II hand-held

4

Tel: +49-(0)721/9497-290 Fax: +49-(0)721/9497-129 E-mail: infoicp@comsoft.de
DirectIndustry's Virtual Technical Library: PDF Catalogue | Technical Documentation | Brochure | Manual | Industrial directory | Specifications | Characteristics
Search Go
Contents table
page 1 p.1
page 2 p.2
page 3 p.3
page 4 p.4
page 5 p.5
page 6 p.6
page 7 p.7
page 8 p.8
page 9 p.9
page 10 p.10
page 11 p.11
page 12 p.12
page 13 p.13
page 14 p.14
page 15 p.15
page 16 p.16
page 17 p.17
page 18 p.18
page 19 p.19
page 20 p.20
page 21 p.21
page 22 p.22
page 23 p.23
page 24 p.24
page 25 p.25
page 26 p.26
page 27 p.27
page 28 p.28
page 29 p.29
page 30 p.30
page 31 p.31
page 32 p.32
page 33 p.33
page 34 p.34
page 35 p.35
page 36 p.36
page 37 p.37
page 38 p.38
page 39 p.39
page 40 p.40
page 41 p.41
page 42 p.42
page 43 p.43
page 44 p.44
page 45 p.45