Issued Aug 2007 Page 1 of 1
Data Sheet For:
Terminal Box
Terminal Box Mounting Flange Details
The Terminal Box isemployed as a deliverypipeline termination. It is used instead of a Dump Valveat the end of a line of series fed reception points and on
systems with only one reception point.The Terminal Box has a much lower profile than a longradius bend termination. It therefore achievestangential entry of material into the reception hopper.Material is deflected through 90° by a deflector platewhich is readily accessible for inspection o Fabricated Mounting Flanges are used to secure Dump Valves manufacturers and Terminal racks to intermediate/termination points and are available in a number of sizes. r replacement. On any size of pipeline, Terminal Boxesand Dump Valves are completely interchangeable.
Dimensions – (mm) Dimensions – (mm) >
Size
A B C D E F KG Size Q R S T U V W X ØY Z >
50
310 30 100 188 253 230 25 50 230 310 280 160 230 200 150 120 18 8 >
80
370 40 123 214 279 290 45 80 288 370 340 170 290 260 208 130 18 8 >
100
370 40 110 214 279 290 45 100 288 370 340 170 290 260 208 130 18 8 >
125
483 50 150 277 342 333 80 125 390 483 442 240 333 293 240 140 18 8 >
150
710 48 210 361 417 440 145 150 558 710 670 320 440 400 308 230 18 8 >
175
710 48 220 361 417 440 160 175 558 710 670 320 440 400 308 230 18 8 >
200
768 44 230 410 456 488 190 200 608 770 720 360 490 440 328 250 18 8 >
250
934 173 290 545 635 604 500 250 780 934 870 435 604 540 440 180 22 14 >
300
960 160 315 570 660 680 800 300 780 960 876 438 680 596 500 200 22 14 >
350
1104 198 350 629 719 754 950 350 910 1100 1030 206 750 680 550 170 22 18 >
Dum p Valve
Pneumatic
C
Terminal Box
See separate Dump Valve Data Sheet Dump
Valve Bod y linde r PneumaticSeal y
Flow of material Bypass Position Dump Position
www.originaldomevalve.com
This leaflet is for guidance only. It does not form part of any contract and is subject to change without notice.