AGD21R-A series
4Pages

{{requestButtons}}

Catalog excerpts

AGD21R-A series - 1

High durability gas valve for high temperature AGD21R-A series HIGH DURABILITY PROCESS GAS VALVE FOR HIGH TEMPERATURE High durability at high temperature (150 °C -200 °C) Actual values achieved more than 100 million times!! *Contact CKD when using integrated type/in the product with a sensor. Durability 30 million times Responds to fluid temperature of 150°C-200°C High response stability Through the special coating of the actuator, an error of 2msec* from the response time reference value is realized even after 30 million times. Response time error Response time ON→OFF Response time OFF→ON High temperature / High Cv value Through channel shape optimization, stable Cv values are realized at high values even at 200°C and after 30 million times of durability test. 0.5 Refer to the usage guidelines on the back and the usage guidelines in “Overall fine dry equipment (Catalog No. CB-035A)” before starting use.

Open the catalog to page 1
AGD21R-A series - 2

AGD21R-A Series ●Air operated metal diaphragm valve Specifications Descriptions Working fluid Proof pressure Working pressure Pa(abs)-MPa(G) Fluid temperature Ambient temperature Storage ambient temperature °C Valve seat leakage External leakage Pa•m3/s(He) Cv value (200°C, negative pressure) Connection Less than 0.4 3/8” JXR male fitting 3/8” JXR female fitting 3/8"Double barbed fitting NC Type (normally closed) Operating pressure Operating port Note 1: Actuator part is less than 110°C Internal structure and parts list Parts name Valve seat Ni-Co alloy Diaphragm Body

Open the catalog to page 2
AGD21R-A series - 3

Series How to order / Dimensions / External view 3/8” JXR male fitting 3/8” JXR female fitting 3/8"Double barbed fitting ● double barbed fitting Custom order External view AGD21R-A with sensor ■ he operation confirmation output when the valve is open T or closed can be taken by the sesnor. Fiber sensor E3X-DA-S series (made by OMRON) 2

Open the catalog to page 3
AGD21R-A series - 4

Before using please be sure to read the "Usage guidelines" and "Usage guidelines" of "Overall dry fine equipment (Catalog No. • This product has been designed so as to satisfy performance at 150°C -200°C. Never use this product outside of the temperature range in the specifications. • Please be careful to not touch with hands or your body because the products are for high temperature. There are cases where touching directly leads to burns. • When piping to the operating port, use the pipe with a heat resistance of more than 110 °C. • Since the fiber part of the product with a sensor breaks...

Open the catalog to page 4

All CKD catalogs and technical brochures

  1. MN4GA / 4GB

    140 Pages

  2. MV3QR

    16 Pages

  3. SCP*3 Series

    60 Pages

  4. SCS2 series

    56 Pages

  5. LMD series

    15 Pages

  6. KBZ series

    64 Pages

  7. WXU series

    32 Pages

  8. AX6000M

    24 Pages

  9. SCS-G Series

    2 Pages

  10. CMK2 SR

    7 Pages

  11. SCPD2 Serie

    3 Pages

  12. SCPD2 Series

    2 Pages

  13. SCPS Series

    1 Pages

  14. SCM Series

    2 Pages

  15. GHV series

    4 Pages

Archived catalogs