video corpo

Solutions for earth leakage protection and circuit breakers with automatic reclosing system
12Pages

{{requestButtons}}

Catalog excerpts

Solutions for earth leakage protection and circuit breakers with automatic reclosing system - 1

Solutions for earth leakage protection and circuit breakers with automatic reclosing system Technology for energy efficiency

Open the catalog to page 1
Solutions for earth leakage protection and circuit breakers with automatic reclosing system - 2

How to enhance electrical quality and continuity for your infrastructures or services by ensuring electrical protection Nowadays, our industrial production processes and the myriad of services for individuals normally entail a constant demand for electrical energy. Electrical service continuity ensures high energy management efficiency in our companies and quality of life for individuals in their homes or places of entertainment. When dealing with electrical protection, one of the most frequently used solutions for protection devices is to cut off the electric supply from affected areas...

Open the catalog to page 2
Solutions for earth leakage protection and circuit breakers with automatic reclosing system - 3

Protection systems with automatic reclosing systems installation's costs intelligent protection, leakage current automatic reclosing system, methods Operates perfectly with maximum currents, earth leakage Earth leakage relays against unwanted prealarm relay reclosing systems status CIRCUTOR offers a wide range of solutions to cater for different types of applications Earth leakage Earth leakage and circuit breaker Circuit breaker Reclosing system Earth leakage • Earth leakage / circuit breaker' Circuit breaker RCCB reclosing system (/„ s 63 A) Programmable earth leakage relay with...

Open the catalog to page 3
Solutions for earth leakage protection and circuit breakers with automatic reclosing system - 4

Comparison table. Protections with reclosing systems A complete range of products for earth leakage protection and installation circuit breakers, capable of covering the needs of each installation. Design of models with special features depending on especipc needs, for example: preventive Reclosing system Associated circuit Classification of models based Customer need Earth leakage Earth leakage Earth leakage Earth leakage Earth Leakage and/or Circuit breaker I Circuit breaker Motorized circuit breaker MT /REC Max MP / MT-FDE Protection features Reclosing system features Time between...

Open the catalog to page 4
Solutions for earth leakage protection and circuit breakers with automatic reclosing system - 5

Earth leakage protection with automatic reclosing system 2/4 poles range, up to 63 A RCCB self-reclosing REC2 / REC2C - 2 poles n x5 40 A 63 A IΔn 30 mA 300 mA Key TEST Opt. output REC2 is a 2 or 4-pole RCCB associated to a compact motor and control set that enables the automatic and safe reclosing of the installation, provided that the leakage is not permanent. The RCCB is reclosed automatically, in accordance with the work mode selected: yyTime sequence mode: After a switch trips, REC2 will make 6 reclosing attempts, with a timer set at 10, 20, 30, 60, 120 and 600 s. If the group can not...

Open the catalog to page 5
Solutions for earth leakage protection and circuit breakers with automatic reclosing system - 6

Earth leakage protection with automatic reclosing system Infrastructures, services, industrial range Ultra-immunized self-reclosing earth leakage relays Toroidal / oval • Public street lighting • Telecommunications centers or service that requires a constant electric supply when maintenance issues

Open the catalog to page 6
Solutions for earth leakage protection and circuit breakers with automatic reclosing system - 7

Earth leakage protection and circuit breaker with self-reclosing system Range of services, industrial Ultra-immunized self-reclosing earth leakage relays ^■MiM With the Certificate of: | DtSPLRY I of Telefonica Espana Espana (Spain) Associated motorized circuit breaker • Shopping malls • Industrial farms • In general, any process or that service requires a constant electric supply when maintenance there is no easy access. ' Other models from 400 A to 630 A

Open the catalog to page 7
Solutions for earth leakage protection and circuit breakers with automatic reclosing system - 8

Circuit Breaker Protection with automatic reclosing system Infrastructures, services, industrial range Relays with automatic reclosing • Shopping malls • Livestock operations • In general, any process or service that requires a constant electric supply when maintenance there is no easy access.

Open the catalog to page 8
Solutions for earth leakage protection and circuit breakers with automatic reclosing system - 9

Application for public lighting The use of earth leakage protection devices with automatic reclosing was al- ready established in Low Voltage Directive ITC-BT-09, which refers to external lighting installations in the section on protection, measurement and control panels (in Spain). The same section also refers to the trip threshold regulation in relation to the earthing resistance measurement during the commissioning of an electric installation service. Our units can be linked to circuit breakers/rearms that are used for the lighting drive system. In turn, these elements are usually...

Open the catalog to page 9
Solutions for earth leakage protection and circuit breakers with automatic reclosing system - 10

Application in industries and offices The dual function of earth leakage protection devices as automatic reclosing elements enables them to be used in earth leakage protection and circuit breaker applications, given that they can be associated to automatic motorised switches. Possible applications of these units in low or zero supervision installations or infrastructures are, among others: yyTelecommunications stations, signalling and control boxes yy Water and gas distributors, pumping blocks yy Photovoltaic installations, panels yy Computer systems, UPS yy Food preservation •...

Open the catalog to page 10
Solutions for earth leakage protection and circuit breakers with automatic reclosing system - 11

P O LLP e rQ111 H i n Management and monitoring software With PowerStudio SCADA you can: • Guarantee the accurate energy supervision of your installation • Achieve the preventive maintenance of all lines and installations The RGU-10 C and CBS-4 C (RAL /MT) series use the standardised Modbus/RTU (RS-485) or Modbus/TCP (Ethernet) protocols, which can be queried from any other market application.

Open the catalog to page 11
Solutions for earth leakage protection and circuit breakers with automatic reclosing system - 12

Designed by: Image and Communications Department - CIRCUTOR, SA Solutions for earth leakage protection and circuit breakers with automatic reclosing system + information: proteccion@circutor.es www.circutor.com CIRCUTOR, SA - Vial Sant Jordi, s/n 08232 Viladecavalls (Barcelona) Spain Tel. (+34) 93 745 29 00 - Fax: (+34) 93 745 29 14 central@circutor.es Code: C2P253-01 CIRCUTOR, SA reserves the right to change all information contained in this catalogue.

Open the catalog to page 12

All CIRCUTOR catalogs and technical brochures

  1. BC48 15V

    4 Pages

  2. TCP2RS+

    4 Pages

  3. LM4I4O-M

    4 Pages

Archived catalogs

  1. Short-Form 2021

    162 Pages

  2. CSB

    2 Pages

  3. RG1M

    2 Pages

  4. RGE

    2 Pages

  5. WGC series

    2 Pages

  6. RGU10

    2 Pages

  7. LVC

    1 Pages

  8. TSA

    2 Pages

  9. R-RE-RBE

    2 Pages

  10. CLZ-FP-HD

    5 Pages

  11. CV

    2 Pages

  12. computer MAX

    2 Pages

  13. LR-LRB

    3 Pages

  14. CR Series

    1 Pages

  15. WI

    2 Pages

  16. MCB

    2 Pages

  17. WGBU

    3 Pages

  18. C80

    4 Pages

  19. AR5L

    9 Pages

  20. TSR

    1 Pages

  21. C-convert

    9 Pages

  22. MEG

    2 Pages

  23. SYNCHROMAX

    3 Pages

  24. UC Series

    3 Pages

  25. SMC-STC

    3 Pages

  26. FMZ-FTZ

    3 Pages

  27. WMC-WTC

    5 Pages

  28. EC-V

    5 Pages

  29. EC-A

    5 Pages

  30. RAPTION 150

    2 Pages

  31. URBAN

    2 Pages

  32. CVM-A Series

    7 Pages

  33. BM-V

    3 Pages

  34. PGR Series

    2 Pages

  35. LM4I/4O-M

    2 Pages

  36. RGU-10B

    2 Pages

  37. CEM-C20

    2 Pages

  38. CEM-C10

    2 Pages

  39. OPTIM-HYB

    2 Pages

  40. RVE2-P

    2 Pages

  41. cSMARTIII

    2 Pages

  42. AR6

    2 Pages

  43. CVM-C5

    2 Pages

  44. FRE

    2 Pages

  45. MT-FDE

    2 Pages

  46. RECmaxMP

    2 Pages

  47. RECmaxLPD

    2 Pages

  48. CBS4

    2 Pages

  49. RGU2

    2 Pages

  50. CIRWATT-B100

    2 Pages

  51. FEMC-FETC

    3 Pages

  52. HC

    2 Pages

  53. BC-V

    3 Pages

  54. BC-A

    3 Pages

  55. TL-5

    1 Pages

  56. CIRWATT-B505

    2 Pages

  57. Type B

    8 Pages

  58. MS

    1 Pages

  59. FLEX-R

    1 Pages

  60. TRMC

    2 Pages

  61. RS2RS

    1 Pages

  62. ReadWatt

    2 Pages

  63. DIR2

    1 Pages