video corpo

MEASUREMENT TRANSFORMERS AND SHUNTS
32Pages

{{requestButtons}}

Catalog excerpts

MEASUREMENT TRANSFORMERS AND SHUNTS - 1

Electrical measurement and control Measurement and Shunts sfo ■m t

Open the catalog to page 1
MEASUREMENT TRANSFORMERS AND SHUNTS - 3

1 M M Electrical measurement and control Measurement Transformers and Shunts The concern to measure the installations consumption or any electrical parameter during the energy management procedures has arisen with the need to trans-form high currents into small currents that can be measured by electronic units . CIRCUTOR offers a solution with a vast range of transformers with different fea-tures that can cater for the main market needs . CIRCUTOR's current transformers have the following features: O 1. Insulation and separation of cirͭcuits and measurement devices from the voltage lines ....

Open the catalog to page 3
MEASUREMENT TRANSFORMERS AND SHUNTS - 4

Untitled table.main {} tr.row {} td.cell {} div.block {} div.paragraph {} .font0 { font:5.00pt "Arial", sans-serif; } .font1 { font:6.00pt "Arial", sans-serif; } .font2 { font:7.00pt "Arial", sans-serif; } .font3 { font:8.00pt "Arial", sans-serif; } .font4 { font:9.00pt "Arial", sans-serif; } .font5 { font:10.00pt "Arial", sans-serif; } .font6 { font:11.00pt "Arial", sans-serif; } .font7 { font:16.00pt "Tahoma", sans-serif; } III. I Measurement Transformers and Shunts p pi P2 Example: Power losses between a transformer and measurement equipment (line distance = 10 m) . O In a secondary...

Open the catalog to page 4
MEASUREMENT TRANSFORMERS AND SHUNTS - 5

Measurement Transformers and Shunts mi Transformer saturation In the case of current transformers, they are saturated by overloads in or-der to make sure that the equipment is not damaged from the secondary. The Fs parameter (Safety Factor) shows the number of primary current transmissions the transformer is capable of transferring to the measurement equip-ment before it is saturated . A transformer will become saturated when its primary current or load are above the nominal values . The linearity of the current transformaͭtion between the primary and second-ary decreases, so that the error...

Open the catalog to page 5
MEASUREMENT TRANSFORMERS AND SHUNTS - 7

Measurement Transformers and Shunts Current transformers srie MC Single-phase Efficient current transformers O Transformer range from 150 to 1,500 A O Secondary 250 mV. O Three ranges in the same transformer. O Compatible with the MC product range from CIRCUTOR. Frequency 50 / 60 Hz Isolation voltage 3 kVac Thermal short-circuit current, / 60 /n Dynamic current, /dyn 2,5 Highest current in the material 0,72 kVac Thermal class B (130 °C) Type of encapsulation VO self-extinguishing plastic Safety factor fs 5 Secondary sealable terminals yes Secondary terminals IP 20 Fixing on DIN rail MC1-20...

Open the catalog to page 7
MEASUREMENT TRANSFORMERS AND SHUNTS - 8

III. I Measurement Transformers and Shunts Current transformers srie MC-3 iree-phase Efficient current transformers Current transformers specially designed to be installed above a switch O Transformer range from 63 to 250 A O Secondary 250 mV O Compatible with the MC product range from CIRCUTOR. Frequs 50 / 60 Hz Isolation voltage 3 kVac Thermal short-circuit current, /th 60 /n Dynamic current, /dyn 2,5 /th Highest current in the material 0,72 kVac Clase 0,5 Thermal class B (130 °C) Type of encapsulation VO self-extinguishing plastic Safety factor fs 5 Secondary sealable terminals yes...

Open the catalog to page 8
MEASUREMENT TRANSFORMERS AND SHUNTS - 9

Measurement Transformers and Shunts mi Current transformers TC sries Narrow-profile current transformer O Type: bar entrance O Types: from 40 to 4000 A O Internai diameter: from 20 . 3 to 63 mm, de- pending on the type O Busbar dimensions: from 25 x 5 mm to 30 x 100 mm O Transformer certificate sheet is attached O DIN rail fixing accessory (Types TC5 and TC6) O Secondary coding types . . . /5 A (on de-mand . . . /1 A . TC12 not availabla) Frequency 50 / 60 Hz Isolation voltage 3 kV ac Thermal short-circuit current, / 60 /n Dynamic current, /dyn 2 5 /th Highest current in the material 0 . 72...

Open the catalog to page 9
MEASUREMENT TRANSFORMERS AND SHUNTS - 11

Measurement Transformers and Shunts mi Current transformers TC sries Narrow-profile current transformer

Open the catalog to page 11
MEASUREMENT TRANSFORMERS AND SHUNTS - 12

III. I Measurement Transformers and Shunts Current transformers TCH Top-performance current transformer [ Description ^ O Narrow-profile O Types: from 100 to 4000 A O Internai diameter: from 26 to 63 mm, de- pending on the type O Busbar dimensions: from 30 x 10 mm to 30 x 100 mm O Transformer certificate sheet is attached Frequency 50 / 60 Hz Isolation voltage 3 kV ac Thermal short-circuit current, / 60 /n Dynamic current, /dyn 2 -5 /th Highest current in the material 0 . 72 kV ac Thermal class B130 °C Working temperature -5 . . . 40 °C Type of encapsulation VO self-extinguishing plastic...

Open the catalog to page 12
MEASUREMENT TRANSFORMERS AND SHUNTS - 14

III. I Measurement Transformers and Shunts Current transformers TA Large-scale current transformer Features O Types: from 750 to 5000 A O Busbar dimensions: from 20 x 100 mm to 60 x 125 mm O Transformer certificate sheet is attached Frequency 50 / 60 Hz Isolation voltage Thermal short-circuit current, /th Dynamic current, /dyn Highest current in the material Thermal class Type of encapsulation Safety factor Secondary sealable terminals 3 kV ac 60 /n 2 5 /th 0 . 72 kV ac 105 °C VO self-extinguishing plastic < 5 Yes Standards IEC 44-1, UNE 21 088-1, UL 94, VDE 0414 Converting a high nominal...

Open the catalog to page 14
MEASUREMENT TRANSFORMERS AND SHUNTS - 16

III. I Measurement Transformers and Shunts Current transformers TP Split-core current transformer O The most important features of these transformers are that they are "disassemblable" . In other words, the whole installation does not have to be disassembled . O Types: from 100 to 5000 A O Busbar dimensions: from 20 x 30 mm to 80 x 160 mm O Transformer certificate sheet is attached Frequency 50 / 60 Hz Isolation voltage Thermal short-circuit current, /th Dynamic current, /dyn Highest current in the material Thermal class Working temperature Transformer ratio Type of encapsulation Secondary...

Open the catalog to page 16
MEASUREMENT TRANSFORMERS AND SHUNTS - 18

III. I Measurement Transformers and Shunts Current transformers TA 210 High-accuracy wound primary current transformer Types: from 5 to 400 A Wound primary Converting a high nominal current to a lower current so that it can be measured by the unit In installations where the nominal current is not too high or where the current requested from the secondary power transformer does not ex-ceed 10 VA . Type TA 210 Wound Primary Dimensions (mm) a a b c 104 5 134 VA Class Code A 0,5 1 3 5/5 15 20 30 [*] M70541 10/5 15 20 30 [*] M70542 15/5 15 20 30 [*] M70543 20/5 15 20 30 [*] M70544 25/5 15 20 30...

Open the catalog to page 18

All CIRCUTOR catalogs and technical brochures

  1. BC48 15V

    4 Pages

  2. TCP2RS+

    4 Pages

  3. LM4I4O-M

    4 Pages

Archived catalogs

  1. Short-Form 2021

    162 Pages

  2. CSB

    2 Pages

  3. RG1M

    2 Pages

  4. RGE

    2 Pages

  5. WGC series

    2 Pages

  6. RGU10

    2 Pages

  7. LVC

    1 Pages

  8. TSA

    2 Pages

  9. R-RE-RBE

    2 Pages

  10. CLZ-FP-HD

    5 Pages

  11. CV

    2 Pages

  12. computer MAX

    2 Pages

  13. LR-LRB

    3 Pages

  14. CR Series

    1 Pages

  15. WI

    2 Pages

  16. MCB

    2 Pages

  17. WGBU

    3 Pages

  18. C80

    4 Pages

  19. AR5L

    9 Pages

  20. TSR

    1 Pages

  21. C-convert

    9 Pages

  22. MEG

    2 Pages

  23. SYNCHROMAX

    3 Pages

  24. UC Series

    3 Pages

  25. SMC-STC

    3 Pages

  26. FMZ-FTZ

    3 Pages

  27. WMC-WTC

    5 Pages

  28. EC-V

    5 Pages

  29. EC-A

    5 Pages

  30. RAPTION 150

    2 Pages

  31. URBAN

    2 Pages

  32. CVM-A Series

    7 Pages

  33. BM-V

    3 Pages

  34. PGR Series

    2 Pages

  35. LM4I/4O-M

    2 Pages

  36. RGU-10B

    2 Pages

  37. CEM-C20

    2 Pages

  38. CEM-C10

    2 Pages

  39. OPTIM-HYB

    2 Pages

  40. RVE2-P

    2 Pages

  41. cSMARTIII

    2 Pages

  42. AR6

    2 Pages

  43. CVM-C5

    2 Pages

  44. FRE

    2 Pages

  45. MT-FDE

    2 Pages

  46. RECmaxMP

    2 Pages

  47. RECmaxLPD

    2 Pages

  48. CBS4

    2 Pages

  49. RGU2

    2 Pages

  50. CIRWATT-B100

    2 Pages

  51. FEMC-FETC

    3 Pages

  52. HC

    2 Pages

  53. BC-V

    3 Pages

  54. BC-A

    3 Pages

  55. TL-5

    1 Pages

  56. CIRWATT-B505

    2 Pages

  57. Type B

    8 Pages

  58. MS

    1 Pages

  59. FLEX-R

    1 Pages

  60. TRMC

    2 Pages

  61. RS2RS

    1 Pages

  62. ReadWatt

    2 Pages

  63. DIR2

    1 Pages