You may also be interested in
Solenoid valve, Pressure controller, Miniature regulator, Stainless steel valve, High pressure regulator
Text version of the page
Untitled
table.main {}
tr.row {}
td.cell {}
div.block {}
div.paragraph {}
.font0 { font:6.00pt "Impact", sans-serif; }
.font1 { font:15.00pt "Tahoma", sans-serif; }
.font2 { font:19.00pt "Tahoma", sans-serif; }
.font3 { font:6.00pt "Verdana", sans-serif; }
.font4 { font:7.00pt "Verdana", sans-serif; }
.font5 { font:9.00pt "Verdana", sans-serif; }
.font6 { font:17.00pt "Verdana", sans-serif; }
.font7 { font:18.00pt "Verdana", sans-serif; }
J^fMHRCLE SEAL CONTROLS, INC.
iiuu séries
4 to 2400 Cut-out Pressure Gauge Protec
Protection against surge or shockwaves
» Snubbing action to reduce shock to gauge_
» Contact seals to ensure précise, unfailing opération
Technical Data
BODYCONSTRUCTION MATERIALS Aluminum, brass, steel, 303 stainless steel 0-RING MATERIALS | Buna N, neoprene, Teflon8 and Viton8
OPERATING PRESSURE PROOF PRESSURE RATED BURST PRESSURE TEMPERATURE RANGE
"| 0 to 6000 psig (414 bar) 110,000 psig (690 bar)
20,000 psig (1,379 bar) minimum I -100° F to +450° F (-73° C to +232° F)
LEAKAGE
Based on o-ring & body material, see "How to Order" I None
Note: Proper filtration is recommended to preventdamage to sealing surfaces.
How it Works
nu
Open
Relief unit, set at maximum gauge pressure, is closed. Check valve unit is open, allowing System pressure to pass into gauge.
Closing
When maximum pressure of gauge is reached, relief valve opens, preventing any further pressure increase. Check valve immediately closes.
Closed
Check valve isolâtes gauge from System. Relief valve closes, trapping pressure in gauge. Check valve reopens when systerr pressure is reduced.
Circle Seal Controls
2301 Wardlow Circle • Corona, CA 92880 Phone (951) 270-6200 • Fax (951) 270-6201 www.circle-seal.com
|
|