You may also be interested in
Infrared sensor, Videographic recorder, Image sensor, Platinum temperature sensor, Probe
Text version of the page
TERMINAL BOARDA B C E Line AMeasuring input/control output 1/power supplyLine BCommunications/remote contacts input11 21 41 51No. Voltage (current *) T/C RTD No. RS-232C RS-422A RS-48512 14 22 24 32 42 44 52 54 1+11SD SDA SA13 43 2+A12SDB SB34 50 49 4847 46 3B13RD RDAMeasuring input 15 45 55 53 4B14RDBCommunications interface 26 25 23 56*For current input 15SG SG SGConnect a shunt resistor (250 , sold separately) to + and – terminals. 27 57On-off pulse type multiple output 1 (On-off pulse output) SSR drive pulse type Current output type Voltage output type On-off servo type See 16 DI1+ No.Line C17DI2+6H (NC)+18 9 8 7 6 5 3 1 2 4 39 38 3736 35 33 31DI3+7 10 40Control output 1 (heating) C (COM)19 20 19 18 17 16 30 29 28 50 59 58DI4+8L (NO)Remote contacts input 20DI-COMNote) 1. All terminal screws are M3.5. 2. For Y-tip or O-tip, use it with the outside dimension of 7mm or less.9L (live)Power 10N (Neutral) Line C Retransmission output/control output 2/CT/event output … differs on output type of heating control. Line E Remote contacts input, etc.No. Standard No. On-off servo type No. Multiple type No.21+21 21+21+Retransmission output (On-off servo type only) 22Retransmission output22 R1 (open) 22Retransmission output22 23 H (NC)+23 RC (common) 23 23+Remote input24C (COM) 24 R2 (close) 24 24 Multiple output 3 (Current output)+25 L (NO)Control output 2 (cooling)25 M3 (close) 25Multiple output 2 (SSR drive pulse)25M 100 to 2k26CT26 M2 (open) 26+26R/L+ Remote/Local27CT CT input27 M1 (common)Power27 27 R/L-COM*28EV1 EV1 EV1 Buffer relay28Buffer relay28Buffer relay28EV3 Buffer relay29EV2 EV2 EV2 Buffer relay COM12 COM1229Buffer relay29Buffer relay29EV4 Buffer relay30COM12 Power30Power30Power30COM34 Power Note) The retransmission output is in for on-off servo type and in for other types.Line E Line C* R/L: Analog remote/local switching (ON: Remote, OFF: Local)DIMENSIONS AND PANEL CUTOUT(Steel plate with thickness of 1 to 10mm is recommended for installation.)ACCESSORIES(Separate purchase is required.) Accessory Remarks CT (current transformer) Recommendation: Model CTL-6-S-H Terminal cover The depth is extended to 132mm by the terminal cover. Shunt resistor for current input(250 Ω )For measurement by DC current of 4 to 20mASpecifications subject to change without notice. Printed in Japan (I) 2002.132-8, KUMANO-CHO, ITABASHI-KU, TOKYO 173-8632 PHONE: +81-3-3956-2171 FAX: +81-3-3956-0915 E-mail: inter@chino.co.jp 32-8, KUMANO-CHO, ITABASHI-KU, TOKYO 173-8632 PHONE: +81-3-3956-2171 FAX: +81-3-3956-0915 E-mail: inter@chino.co.jpWebsite: http://www.chino.co.jp Website: http://www.chino.co.jp4 4 |
|