Thyristor Regulators Single-phase
4Pages

{{requestButtons}}

Catalog excerpts

Thyristor Regulators Single-phase - 1

Compact structure Compact, lightweight and high panel installationdensity Setting unit (option) Display of various parameters, voltage/current / power and change of the feedback system arepossible. Options The options of heater disconnection alarmfunction and current limit function are available. Various protections functions built-in The thyristor element is protected by melting o f the rapid fuse for short-circuit of load, and b y Phase-angle firing/zero-cross firing gate-off for over-current. For models with acooling fan built-in, alarm is activated and outputis stopped for abnormal heat-sink temperature. The phase-angle firing system and thezero-cross firing system are selectable. The running by the phase-angle firing system at theinitial stage and by the zero-cross firing systemat the normal stage is possible. Self-diagnosis function built-in Zero-cross firing system The self-diagnosis function is built in fo r With the delta-sigma modulation, which controlsevery 1 cycle, the fine control like thephase-angle firing system is possible. abnormal operation, abnormal thyristor elementand abnormal power supply. > 1

Open the catalog to page 1
Thyristor Regulators Single-phase - 2

Power supply 10: 100V 11: 110V 12: 120V 20: 200V 22: 220V 24: 240V 38: 380V 40: 400V 44: 440V 99: Others Rated current 010: 10A 020: 20A 030: 30A 050: 50A 075: 75A 100: 100A 150: 150A 200: 200A 250: 250A 300: 300A 400: 400A 500: 500A 750: 750A X00: 1000A Control system/feedback type V: Phase-angle firing voltage feedback / Zero-cross firing A: Phase-angle firing ׷ current feedback / Zero-cross firing W: Phase-angle firing power feedback / Zero-cross firing N: Phase-angle firing ׷ no-feedback * > 1 / Zero-cross firing C: Zero-cross firing Rapid fuse A; Built-in N: Not provided Setting unit...

Open the catalog to page 2
Thyristor Regulators Single-phase - 4

Setting unit Setting: Output (0 to 100%), high/low limits (0 to 100%),ramp setting (0 to 100%), soft-start time setting (1 to 20seconds), heater disconnection alarm setting (loadresistance 0 to 100%, available in models with heate Power supply: Supplied from thyristor unit Working temperature: -10 to 55C Working humidity: 30 to 90%RH (no dew condensation) Weight: About 50g Heater disconnection alarm Detects the heater disconnection by built-in or external CT.When disconnection is detected, LED blinks and alarmcontact output becomes ON. The selection of phase-anglefiring system/zero-cross...

Open the catalog to page 4

All CHINO CORPORATION catalogs and technical brochures

  1. LH100

    4 Pages

  2. IR-FA SERIES

    6 Pages

  3. IR-TA SERIES

    2 Pages

  4. MODEL IR-TE

    2 Pages

  5. TRAMS III

    4 Pages

  6. IR-CZQH

    2 Pages

  7. On-line model

    12 Pages

  8. C800

    4 Pages

  9. IR-R0A

    2 Pages

  10. R000

    4 Pages

  11. HN-EK

    2 Pages

  12. HN-EH

    2 Pages

  13. IR-HA

    2 Pages

  14. IR-TE

    2 Pages

  15. DP2000G

    4 Pages

  16. KP3000

    6 Pages

  17. KR3S

    6 Pages

  18. KR5100

    4 Pages

  19. IR-BZ

    2 Pages

  20. MILA-C5000PN

    4 Pages

  21. KR3000

    6 Pages

  22. Solidpak NC

    6 Pages

  23. Data Scanner

    4 Pages

Archived catalogs

  1. TP

    4 Pages

  2. EH3000 PEN

    4 Pages

  3. KH4000

    6 Pages

  4. KL4000

    6 Pages

  5. AH4000 PEN

    8 Pages

  6. AL4000 PEN

    6 Pages

  7. KR2S

    6 Pages