Group: Industrial Process Instrumentation
Catalog excerpts
EL3000 SERIES 100mm CHART ANALOG RECORDER (PEN WRITING TYPE) EL 3000 series are analog recorders sized 144 x 144mm with 100mm width chart which have 3 types of 1-pen, 2-pen and 3-pen. The unit starts recording as soon as the power supply and input are connected and it is also easy to operate. Scale plate, input range and function of the recorder can be selected for various purpose and applications as many kinds of options are prepared. FEATURES Universal power supply Universal power supply with voltage range of 100 to 240V AC is applied. (50/60Hz switchable) Linear temperature scale Temperature scale of thermocouple and resistance thermometer input is a linear scale that is excellent in reading indication value. Standard 6 chart speeds 6 chart speeds (5,10,20,40,80,160mm/h) are switchable as standard. 5 chart speed and hour/minute change are prepared as option. Unit structure and light-weight Light-weight (50% of the previous unit weight) was realized by easy maintenance unit structure. Alarm setting (individual input alarm) as standard Higher and lower limit alarm can be programmed for each channel. Alarm value is easy to be programmed by pointer location. You can check the alarm by front LED lighting. Alarm output is prepared as option. EL3 Input signals 5 : Thermocouple/DC voltage 7 : Resistance thermometer Thermocouple with burnout/DC voltage Built-in voltage divider input (option)*1 Input and scale plate (option) 0 : Standard input + standard scale plate 1 : Non-standard input (Including current input, and built-in voltage divider) + standard scale plate 2 : Standard input + non-standard scale plate 3 : Non-standard input (Including current input, and built-in voltage divider) + Non-standard scale plate Alarm output (option) 0 : None 1 : 2 alarm outputs Chart speed and burnout (option) 0 : 6-speed+ burnout disabled 1 : 6-speed + up-scale burnout 2 : 6-speed + down-scale burnout A : 5-speed hour/minute change + burnout disabled B : 5-speed hour/minute change + up-scale burnout C : 5-speed hour/minute change+ down-scale burnout) *1: Optional built-in voltage divider and thermocouple/resistance thermometer burnout input is only type "7". *2: Input and scale selection are needed for non-standard input and non-standard scale plate. 1st pen must be selected as thermocouple input. *3 Burnout are programmed together for all channels for thermocouple/ resistance thermometer input. Input points F : 2 pen G : 3 pen 1st pen input and scale plate*2 0 : Standard input + standard scale plate 1 : Non-standard input (Including current input and built-in voltage divider) +standard scale plate 2 : Standard input + non-standard scale plate 3 : Non-standard input (Including current input and built-in voltage divider) +non-standard scale plate 2nd pen input and scale plate*2 0 : Standard input + standard scale plate 1 : Non-standard input (Including current input and built-in voltage divider) +standard scale plate 2 : Standard input + non-standard scale plate 3 : Non-standard input (Including current input and built-in voltage divider) +non-standard scale plate 3rd pen input and scale plate*2 N : None (for 2 pen) 0 : Standard input + standard scale plate 1 : Non-standard input (Including current input and built-in voltage divider)+ standard scale plate 2 : Standard input + non-standard scale plate 3 : Non-standard input (Including current input and built-in voltage divider) +non-standard scale plate Alarm output (option) 0 : None 2 : Alarm output 4points/6points (2-pen type : 4 points, 3-pen type : 6 points) Chart speed and burnout (option)*3 0 : 6-speed + burnout disabled 1 : 6-speed + up-scale burnout 2 : 6-speed + down-scale burnout A : 5-speed hour/minute change + burnout disabled B : 5-speed hour/minute change + up-scale burnout C : 5-speed hour/minute change + down-scale burnout
Open the catalog to page 1OPERATION / PROGRAMMING SPECIFICATIONS INPUT SPECIFICATIONS Measuring channels : Reference range and types : 1, 2, 3 channels DC voltage --- ±13.8mV, ±27.6mV, ±69mV, ±200mV, ±500mV, ±2V, ±5V Built-in voltage divider (option) ; ±10V, ±25V, ±50V DC current --- External installation of shunt resister (250Ω) is applied (option) Thermocouples --- K, E, J, T, R, B (option) Resistance thermometer --- Pt100 (1997) (Measured current ; 1mA) *Linear scale for thermocouple and resistance thermometer Input designation : Refer to above reference range Single scale Accuracy rating : ±0.5% of input span...
Open the catalog to page 2OPTION SPECIFICATIONS Options Alarm output DC current input Built-in voltage divider Non-standard input Non-standard scale plate Standard range and minimum width of scale Contents Alarm contact output is available Alarm relay --- Individual mechanical relay a contact, 2 outputs (common) Maximum contact rating --250V AC 2A, 30V DC 2A(resistive load) 250V AC 0.5A, 30V DC 0.5A (inductive load)) 250Ω of shunt resistor is applied to measure voltage input Built-in voltage divider(1/1000) measures input in the range of ±5V to ±50V (input type "7" only for 1-pen type) Refer to the table of standard...
Open the catalog to page 3TERMINAL BOARD 1-Pen type Panel cutout Minimum clearance for plural installation Unit: mm Mounting bracket Specifications subject to change without notice. Printed in Japan (I) 2008. Unit: mm Paper 11. Recycled 32-8, KUMANO-CHO, ITABASHI-KU, TOKYO 173-8632 PHONE: +81-3-3956-2171 FAX: +81-3-3956-0915 E-mail: inter@chino.co.jp Website: http://www.chino.co.jp
Open the catalog to page 4All CHINO CORPORATION catalogs and technical brochures
-
Pt-Co Temperature Probe
2 Pages
-
LH100
4 Pages
-
ELECTRONIC MINI-RECORDER
2 Pages
-
MR SERIES CARD LOGGERS
8 Pages
-
IR-BAT SERIES
4 Pages
-
IR-FA SERIES
6 Pages
-
IR-TA SERIES
2 Pages
-
MODEL IR-TE
2 Pages
-
IR-CZQW series
2 Pages
-
TRAMS III
4 Pages
-
General Catalog
14 Pages
-
IR-CZQH
2 Pages
-
On-line model
12 Pages
-
C800
4 Pages
-
KT-H503/KT-H504
2 Pages
-
IR-R0A
2 Pages
-
R000
4 Pages
-
HN-EK
2 Pages
-
HN-EH
2 Pages
-
IR-HA
2 Pages
-
IR-TE
2 Pages
-
DP2000G
4 Pages
-
KP3000
6 Pages
-
AL4000 Dot-printing
6 Pages
-
AH4000 Dot-printing
6 Pages
-
KR3S
6 Pages
-
KR5100
4 Pages
-
HYBRID MEMORY RECORDER
8 Pages
-
GRAPHIC RECORDER
6 Pages
-
IR-BZ
2 Pages
-
MILA-C5000PN
4 Pages
-
Three-Phase JW
6 Pages
-
Single-phase JU
4 Pages
-
On-line model IR-SA
4 Pages
-
Strip Chart Recorder ES600
2 Pages
-
KR3000
6 Pages
-
Sheathed Thermocouples
12 Pages
-
Solidpak NC
6 Pages
-
Fiber optic model
6 Pages
-
Thermal Imaging Sensor
4 Pages
-
Digital Program Setter
6 Pages
-
Data Scanner
4 Pages
-
Hybrid Recorder
6 Pages
-
Hybrid Memory Recorder
6 Pages
Archived catalogs
-
SOFC Testing System FC5300
1 Pages
-
TP-S ( Termal image )
2 Pages
-
TP
4 Pages
-
EH3000 PEN
4 Pages
-
KH4000
6 Pages
-
KL4000
6 Pages
-
AH4000 PEN
8 Pages
-
AL4000 PEN
6 Pages
-
KR2S
6 Pages
-
Temperature Logger: MR5300
8 Pages
-
Strip Chart Recorder: LE5000
8 Pages
-
Graphic Recorder: KR2000
6 Pages
-
Ubiquitous Recorder
4 Pages