Group: Industrial Process Instrumentation
Catalog excerpts
ISTANDARD PLATINUM RESISTANCE THERMOMETERS ISTANDARD PLATINUM-COBALT RESISTANCE THERMOMETER These are standard temperature sensors conforming to the International Temperature Scale of 1990. The temperature range from 4 K to 962 °C is measured by there sensors which are classified into a standard platinum-cobalt resistance thermometer for cryogenic temperature, standard platinum resistance themometers for low temperature, medium temperature and high temperature. The R800 series standard platinum resistance thermometers, which have been commercialized under the guidance of the NMIJ, have been adopted by national metorology institute in overseas countries with reputation on their performance and reliability. •These sensors are manufactured with selected quality materials by highly skilled manufacturing techniques under •The standard platinum resistance thermometer for low temperature is the first international product in Japan as the standard thermometer applicable to 13 K. •The standard platinum resistance thermometers for medium temperature and for high temperature have been delivered to national measurement institute in overseas countries in large quantities. Its performance has been highly reputed in Comite Consultatif de Thermometrie (CCT). •The standard platinum-cobalt resistance thermometer for cryogenic temperature features excellent reproducibility and stability in a cryogenic temperature range below to 4 K. ILIST OF STANDARD TEMPERATURE SENSORS STANDARD STANDARD PLATINUM TEMPERATURE — RESISTANCE THERMOMETERS - -STANDARD PLATINUM-COBALT RESISTANCE THERMOMETER FOR CRYOGENIC TEMPERATURE -STANDARD PLATINUM RESISTANCE THERMOMETER FOR LOW TEMPERATURE MODEL R800-0 - STANDARD PLATINUM RESISTANCE THERMOMETER FOR MEDIUM TEMPERATURE MODEL R800-2 - STANDARD PLATINUM RESISTANCE THERMOMETER FOR HIGH TEMPERATURE MODEL R800-3 - LOW RESISTANCE TYPE STANDARD PLATINUM RESISTANCE THERMOMETER FOR HIGH TEMPERATURE
Open the catalog to page 1STANDARD PLATINUM RESISTANCE THERMOMETER FOR LOW TEMPERATURE (CAPSULE TYPE) MODEL R800-0 CALIBRATION For applying this thermometer as a standard temperature sensor, the temperature-resistance value table must be prepared by calibrating it. CHINO will prepare a temperature-resistance value table at CHINO’s standard laboratory if requested. (Calibration charge is separately asked.) CALIBRATION TEST (CRYOGENIC CALIBRATION TEST L-5) MEASURING TEMPERATURE RANGE : 13 K to 30 ºC RESISTANCE VALUE : 25.5 ± 1 Ω (at 0 ºC) SPECIFIED CURRENT : 1 mA TEMPERATURE CHARACTERISTIC : R (-38.8344 ºC) / R (0.01...
Open the catalog to page 2STANDARD PLATINUM RESISTANCE THERMOMETER FOR MEDIUM TEMPERATURE (STEM TYPE) For applying this thermometer as a standard temperature sensor, the temperature-resistance value table must be prepared by calibrating it. CHINO will prepare the temperature-resistance value table at CHINO's standard laboratory if requested. (Calibration charge is separately asked.) CALIBRATION TEST (FIXED POINT CALIBRATION TEST F-1) MODEL R800-2 This thermometer is designed as a stem type standard temperature sensor with a quartz protecting tube covering the temperature range from 73 K to 933.473 K (660.323 ºC,...
Open the catalog to page 3STANDARD PLATINUM RESISTANCE THERMOMETER FOR HIGH TEMPERATURE (STEM TYPE) STANDARD PLATINUM RESISTANCE THERMOMETER FOR HIGH TEMPERATURE (STEM TYPE) MODEL R800-3 This thermometer using a high purity platinum wire with a large diameter as a temperature sensing wire is designed as a stem type standard temperature sensor covering the temperature from 273.15 K (0 ºC) to 1234.93K (961.78 ºC, freezing point of silver). MODEL R800-3L This thermometer using a high purity platinum wire with a large diameter as a temperature sensing wire is designed as a stem type standard temperature sensor covering...
Open the catalog to page 4CALIBRATION POINT : Freezing point of silver Freezing point of aluminum Freezing point of zinc Freezing point of tin Triple point of water CALIBRATION UNCERTAINTY : ± 0.06 ºC PROTECTING SPRING CALIBRATION TEST (FIXED POINT CALIBRATION TEST F-0) PROTECTING TUBE (Quartz glass) TERMINAL BOX(Bakelite) TEMPERATURE-RESISTANCE VALUE TABLE The temperature-resistance value table will be prepared by interpolating the R (t) values between 660 ºC and 962 ºC at intervals of 1 K according to the calibrated values in the calibration test. LEAD WIRE MODEL R800-4 STANDARD PLATINUM-COBALT RESISTANCE...
Open the catalog to page 5PERFORMANCE SPECIFICATION ■STANDARD TEMPERATURE SENSORS •TRIPLE POINT OF OXYGEN TRIPLE POINT • TRIPLE POINT OF ARGON VAPOR PRESSURE POINT OF EQUILIBRIUM HYDROGEN 17 035 K TRIPLE POINT OF MERCURY VAPOR PRESSURE POINT OF TRIPLE POINT POINT FREEZING POINT FREEZING POINT OF COPPER FREEZING POINT OF GOLD FREEZING POINT OF SILVER Pt-Co RESISTANCE THERMOMETER CAPSULE TYPE Pt RESISTANCE THERMOMETER STEM TYPE Pt RESISTANCE THERMOMETER STEM TYPE Pt RESISTANCE THERMOMETER RADIATION THERMOMETERS Specifications subject to change without notice. Printed in Japan (I) 2013. 7 CHINO CORPORATION E-mail :...
Open the catalog to page 6All CHINO CORPORATION catalogs and technical brochures
-
Pt-Co Temperature Probe
2 Pages
-
LH100
4 Pages
-
ELECTRONIC MINI-RECORDER
2 Pages
-
MR SERIES CARD LOGGERS
8 Pages
-
IR-BAT SERIES
4 Pages
-
IR-FA SERIES
6 Pages
-
IR-TA SERIES
2 Pages
-
MODEL IR-TE
2 Pages
-
IR-CZQW series
2 Pages
-
TRAMS III
4 Pages
-
General Catalog
14 Pages
-
IR-CZQH
2 Pages
-
On-line model
12 Pages
-
C800
4 Pages
-
KT-H503/KT-H504
2 Pages
-
IR-R0A
2 Pages
-
R000
4 Pages
-
HN-EK
2 Pages
-
HN-EH
2 Pages
-
IR-HA
2 Pages
-
IR-TE
2 Pages
-
DP2000G
4 Pages
-
KP3000
6 Pages
-
AL4000 Dot-printing
6 Pages
-
AH4000 Dot-printing
6 Pages
-
KR3S
6 Pages
-
KR5100
4 Pages
-
HYBRID MEMORY RECORDER
8 Pages
-
GRAPHIC RECORDER
6 Pages
-
IR-BZ
2 Pages
-
MILA-C5000PN
4 Pages
-
Three-Phase JW
6 Pages
-
Single-phase JU
4 Pages
-
On-line model IR-SA
4 Pages
-
Strip Chart Recorder ES600
2 Pages
-
KR3000
6 Pages
-
Sheathed Thermocouples
12 Pages
-
Solidpak NC
6 Pages
-
Fiber optic model
6 Pages
-
Thermal Imaging Sensor
4 Pages
-
Digital Program Setter
6 Pages
-
Data Scanner
4 Pages
-
Hybrid Recorder
6 Pages
-
Hybrid Memory Recorder
6 Pages
Archived catalogs
-
SOFC Testing System FC5300
1 Pages
-
TP-S ( Termal image )
2 Pages
-
TP
4 Pages
-
EH3000 PEN
4 Pages
-
KH4000
6 Pages
-
KL4000
6 Pages
-
AH4000 PEN
8 Pages
-
AL4000 PEN
6 Pages
-
KR2S
6 Pages
-
Temperature Logger: MR5300
8 Pages
-
Strip Chart Recorder: LE5000
8 Pages
-
Graphic Recorder: KR2000
6 Pages
-
Ubiquitous Recorder
4 Pages