1 kA / 10 kA AmpFLEXTM Portable, on-site and laboratory test and measurement instruments  2009 catalogue Page  97 Flexible current sensors 20 A / 200 A The range is composed of 9 standard models* dedicated to the measurement of AC currents from 0.5 A to 10 kA, at industrial frequencies. Each flexible core (48, 80 or 120 cm long depending on the model) is connected by a shielded cable to a small box containing the processing electronics and a standard 9 V battery. The distance between the sockets (19 mm) facilitates direct connection to any type of multimeter, tester or recorder equipped with an AC voltage input (impedance Z > 1 MÙ). The quick and simple system for opening/closing the core makes it easy to handle even with safety gloves. Other strong points: very lightweight (no magnetic circuit), no saturation effect, highly accurate and very little phase shift (for wattmeter measurements). AmpFLEX™ Flexibility and easy handling for clamping any conductor * Specific models on request: consult us concerning the possible sensitivities (mV/A) and lengths. We can also supply bare sensors for incorporation in assemblies including the signal processing electronics. - + AmpFLEXTM References to order Accessories / Spares > Bring unlimited autonomy to your AmpFLEX™: replace the battery with the mains adapted plug Adaptator for AmpFLEXTM > P01101968 0.5 … 20A 0.5 … 200A 2 V AC 2 V AC 0.5 … 2,000A 0.5 … 2,000A 0.5 … 200A 0.5 … 2,000A 0.5 … 200A 0.5 … 2,000A 0.5 … 300A 0.5 … 3,000A 0.5 … 300A 0.5 … 3,000A 0.5 … 300A 0.5 … 3,000A 0.5 … 1,000A 0.5 … 10,000A 1A / 100mV 1A / 10mV 1A / 10mV 1A / 1mV 1A / 10mV 1A / 1mV 1A / 10mV 1A / 1mV 1A / 10mV 1A / 1mV 1A / 10mV 1A / 1mV 1A / 1mV 1A / 0.1mV 10 … 20kHz 1 % 1 % 1 % 1 % 1 % 1 % 1 % 1 % 1 % 10 … 20kHz 10 … 20kHz 10 … 20kHz 10 … 20kHz 10 … 20kHz 10 … 20kHz 10 … 20kHz 10 … 20kHz 1A / 1mV 2 V AC 1A / 1mV 2 V AC 2 V AC 3 V AC 3 V AC 3 V AC 1 V AC Very low current Low current Medium current Hot current Current Voltage Leads + safety plug ø 4 mm(2) Female sockets ø 4 mm BNC connector (oscilloscopes) Automatic DC zero Power measurement (low phase shift) Bandwith (frequency in Hz) Typical accuracy Transformation ratio (input/output) AC DC Measurement range (1) Output protected against overvoltage Models To order 20A/200A (45 cm) 2 kA (45 cm) 2 kA (80 cm) 200A/2kA (45 cm) 200A/2kA (80 cm) 300A/3kA (45 cm) 300A/3kA (80 cm) 300A/3kA (120 cm) 1/10 kA (120 cm) > P01120503 > P01120501 > P01120502 > P01120504 > P01120505 > P01120506 > P01120507 > P01120508 > P01120509

pageCatalog pdf di En 2012-05-19-13