Design Advantages
• economical fast energy transfer reducing radiation losses
• vertical expansion free centrally suspended heat exchanger with low position blowdown
• replaceable evaporation section
• easy and quick cleaning of the heat exchanger, without removal
• operation without supervision
• full or partial installation on request
• exemplary customer service and spare parts availability
-л.
• space saving
• installation without foundation support
• robust steel fabrication
• patented uninsulated air cooled, double cover
• air intake from the top creating good air circulations within the boiler-house
• integrated, low emission CERTUSS burner system
• noise and vibration reduction, anti-vibration mountings
- К
Dapadties 80-300 kg/h Dapacities 350-600 кдЛ"
Technical Data
on
Capacities
Pressures
Consumption
Measurements (~ mm)
Connections
LICti
up
steam
heat
heat
Stages
working
max. admissible
oil
natural
liquid
height width
depth
steam
flue gas
flue gas
electrical
oil
natural
liquid
feed water
steam
i- о
«Л
output
output
input
pressure max.
pressure
(EL)
gas
gas
tube0
(center)
Wei
-
connection
connection
gas
gas
connection
connection
Cor
kg/h
kW
kW
MPa (bar)
MPa (bar)
kg/h
m3/h
m3/h
А В
С
D
E
F
kW
DN
DN
DN
DN
DN
1
80 120
53 79
58 87
1
0.8-1.4-2.2-2.9 (8-14-22-29)
1.0-1.6-2.5-3.2 (10-16-25-32)
4.9 74
5.8 8.7
2.2 3.4
1500 650
1210
500
180
1050
320
1.75
%■
20
20
1 V/
15
2
150 200
99 131
109 145
1
0.8-1.4-2.2-2.9 (8-14-22-29)
1.0-1.6-2.5-3.2 (10-16-25-32)
9.2 12.3
10.9 14.5
4.2 5.6
1580 725
1375
560
200
1120
420
1.9
%•
32
20
1 V4"
20
250
164
182
15.3
18.2
71
3
300 350
196 230
218 255
1
0.8-1.4-2.2-2.9 (8-14-22-29)
1.0-1.6-2.5-3.2 (10-16-25-32)
18.4 21.5
21.8 25.5
8.4 9.9
1850 805
1510
640
250
1360
520
2.0
%•
40
20
1 V4"
25
400
262
291
24.5
29.1
11.3
4
500 600
328 393
364 436
2
0.8-1.4-1.8-2.2-2.9 (8-14-18-22-29)
1.0-1.6-2.0-2.5-3.2 (10-16-20-25-32)
30.6 36.8
36.4 43.6
14.1 16.9
1980 870
1630
700
250
1460
950
3.6
%■
50
25
1 V/
32
Reference values: Natural gas at 10 kW/Nm3 - 8600 kcal/Nm3, liquid gas at 25.8 kW/Nm3 - 22200 kcal/Nm3
Measurements and weights are rounded up or off. MPa and bar are overpressure values.
For positioning purposes lateral fittings are detachable. Delivery complete with water pump.
Output values stated are related to 100°C feed water temperature with 1 MPa (10 bar) steam overpressure.
CERTUSS construction group 4 also available with combination burner oil / natural gas.
CERTUSS burner with flue gas return (NOx reduction) optional.
CERTUSS steam generators oil/gas, single or in combination meet all requirements within seven construction groups
Rights reserved for technical alterations.
Universal range 700-1800 kg/h and electrical 8 -97 kg/h
Please ask for brochure
CERTUSS Dampfautomaten GmbH & Co. KG gm ДТ1 ■
■ ■ . ||[ц g UOO
Telefon +49 (0)2151 578-0 • Telefax +49 (0)2151 578-102 űam РлПлиа*Л|.е
internet: www.certuss.com • e-mail: verkaufecertuss.com OĎCQITI уЛсПсГШОГо
1 MPa (10 bar) = 145 psi 10 psi = 0.069 MPa (0.69 bar)
1 kW = 3413 BTU 1000 BTU = 0.293 kW

pageCatalog pdf di En 2012-02-07-14