| GENERAL Full Stroke Ranges.....................................0-3 to 0-30 in. (0-75 to 0-750 mm) Output Signal...................................................voltage divider ( potentiometer) Linearity.............................................± 0.04 to 0.1% full stroke, see ordercode Repeatability................................................................................... < 0.01 mm Resolution.............................................................................essentially infinite Life Expectancy.......................................................................50 million cycles Enclosure Material.............................................................................aluminum Max. Operating Speed..................................................200 inches per second ELECTRICAL Input Resistance................................5K to 10K ohms (±20%), see ordercode Recommended Maximum Input Voltage.............................25-30 V(AC or DC) Recommended Operating Wiper Current...............................................£ 1 /jA ENVIRONMENTAL Enclosure Design.......................................................................................IP65 Operating Temperature................................................................-22° to 212°F Vibration......................................................up to 10 G's to 2000 Hz maximum |