CLP Series - Celesco - #1

/ 1


catalogue search
CLP Series - Celesco
P. 01
Page:
CLP Series - Celesco


See other catalogues for Celesco

Text version of the page
CLP | 9 celesco.com • info@celesco.com tel: 800.423.5483 • +1.818.701.2750 • fax: +1.818.701.2799 Celesco Transducer Products, Inc. 20630 Plummer Street • Chatsworth, CA 91311 electrical strokeCredyellowblackretracted extended Ø.20 [5]1.06 [27]2 ft. [600 mm] long, 22 gauge electrical cablemechanical strokeretracted mounting distanceØ.192 [4.88]*Ø.63 [16].23 [6].32 [8]25º.59 [15] (square)All DIMENSIONS ARE IN INCHES [MM] tolerances are 0.03 IN. [0.5 MM] unless otherwise noted AB*tolerance = +.030 –.000 [+0,76 -0,00] retracted extended Linear Potentiometer CLP Precision Potentiometric Output Ranges: 0-1 to 0-11.5 inches [0-25 to 0-290 mm] 2.5K – 11.6K ohms • IP65 Specification Summary: GENERAL Full Stroke Ranges 0-1 to 0-11.5 in. (0-25 to 0-290 mm) Output Signal . voltage divider (potentiometer) Linearity . ± 0.1 to 0.2% full stroke, see ordercode Repeatability 0.01 mm Resolution . essentially infinite Life Expectancy . > 25 million cycles Operating Speed 400 inches (10 M) per second max. Enclosure Material aluminum Sensor . conductive plastic linear potentiometer Weight 3 - 7 oz. (87 - 197 g.), see ordercode ELECTRICAL Input Resistance 2.5K to 11.6K ohms (±20%), see ordercode Recommended Maximum Input Voltage 42 VDC Recommended Operating Wiper Current . < 1ìA ENVIRONMENTAL Enclosure Design IP65 Environmental Sealing . O-ring and felt shaft seal Operating Temperature . -40º to 212ºF Vibration up to 10 G’s to 2000 Hz maximum Developed specifically to meet the needs of the auto racing industry and proven in industrial applications, Celesco’s CLP series position transducers offer unrivalled performance in terms of accuracy, repeatability, life expectancy and ease of mounting. The combination of individually corrected conductive plastic elements and precious metal wipers provide a cost effective measuring system which can operate effectively without being unduly influenced by external environmental conditions. 6.81 7.80 8.75 9.76 11.73 13.82 15.79 18.27 (± 0.1) in 173 198 222 248 298 351 401 464 (± 2 ) mm 1 2 3 4 6 8 10 11.5 in 25 50 75 100 150 200 250 290 mmA 1.12 2.11 3.09 4.08 6.04 8.13 10.10 11.55 (± 0.02) in 28.5 53.5 78.5 103.5 153.5 206.5 256.5 293.5 (± 0.5 ) mmB 1.06 2.05 3.03 4.02 5.98 8.07 10.04 11.50 in 27.0 52.0 77.0 102.0 152.0 205.0 255.0 292.0 mmCMeasurementRange Ordering Information: measurement range, in. [mm]: resistance, (±20%): weight, oz. [grams]: linearity, %: 1[25] 2[50] 3[75] 4[100] 6[150] 8[200] 10[250] 11.5[290] 2.5K 5.0K 5.0K 5.0K 10K 10K 11.6K 10K 0.2% 0.2% 0.2% 0.2% 0.1% 0.1% 0.1% 0.1% 3.0[87] 3.4[97] 3.8[108] 4.1[117] 4.8[138] 5.5[157] 6.9[197] 6.2[177] CLP-25 CLP-50 CLP-75 CLP-100 CLP-150 CLP-200 CLP-250 CLP-290 Item Number version: 4.0 last updated: December 12, 2006

pageCatalog pdf di En 2012-05-22-28