Text version of the page
Text version of the page
| | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | «eiais | | | | | | THREE PHASE | | | | | | | | | | | | | | Motor control | | | | | | | | | | SG9-SW9 | | Reversing switches | | | | | | | | | | | | | | This relay is used to reverse the rotational direction of a motor. The SW9 series is ready to use with heatsnk and DIN rail mounting integrated. They all come with LED and protection against simultaneous controls. | | | | | | © | | | | | | | | | | | | | | | | | | | | | | | | | | | | PRODUCT REFERENCE | Switching Current AC-53 | Switching voltage | Control Voltage | I2t | Protec. | Specifications | Dimensions mm | Fig n° | | | | SG969100 | 3x6,6A | 24-520VAC | 10-30VDC | 612A2s | reversing time delay | 3 phase switching | 100x73,5x39,5 | 1 | | | | SG969300 | 3x8,5A | 24-520VAC | 12-30VDC | 1500A2s | 2 phase switching | 100x73,5x39,5 | 1 | | | | SV969300 | 3x8,5A | 24-520VAC | 12-30VDC | 1500A2s | 2 phase switding IP20 endosue | 100x76x56,5 | 4 | | | | SV969500 | 3x16A | 24-550VAC | 12-30VDC | 5000A2s | 2 phase switding IP20 endosue | 100x76x56,5 | 4 | | | | SW960330 | 3x4,5A | 24-550VAC | 12-30VDC | 1500A2s | 2 phase switching | 100x76x72 | 2 | | | | SW961230 | 3x8,5A | 24-520VAC | 12-30VDC | 1500A2s | 2 phase switching | 83x90x155 | 3 | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | (4) = 2 without DIN rail | | Standard Entrax : 40mm. Available in 47,6mm (Esuffix) : please contact us | | | | | | ready to use | | | | | | | | | | | | | | Soft Starter SMCV - SMCW | | | | | | | | | MC* | | | | | | | | | | — r Motor control : -> Efficient reduction of torque and starting current Incandescent or infrared lamp starting : -> Reduction of in rush current Increase in life expectancy Transformer control (loaded) : -> Elimination of saturation current -> Improved control and protection Whatever your application : Diagnoss of network, load and state of product -> Better balance of and less interference on starters (full control of the 3 phases!) -> Smple use faciliting implementation and adjustements -> As compact as an electronic contactor | | | | | | © © © © © | | | | | | | | | | PRODUCT REFERENCE | | | | | | Pmax motor 400VAC | | Pmax motor 230VAC | | Max. Current AC53a | | | | | | Dimensions mm | | | | | | Specifications | | | Fig n° | | | | | | | | | | | | | | | | | | | | | | | EN60947-4-2 | | | | | | | | | | | | | | | | | | | | | | | | | SMCV6080 | 7,5kW | 13kW | 4,3kW | 7,5kW | 16A | 11,5A | Heatsnk not provided | 100x76x58,5 | 2 | | | | SMCV6110 | 11kW | 19kW | 6,4kW | 11kW | 25A | 15,5A | | | | SMCV6150 | 15kW | 26kW | 8,6kW | 15kW | 30A | 22,5A | | | | SMCW6020 | 2,5kW | 4,3kW | 1,4kW | 2,5kW | 5,6A | 4A | supplied with built-in heatsnk | 83x110x74 | 1 | | | | SMCW6080 | 7,5kW | 13kW | 4,3kW | 7,5kW | 16A | 11,5A | 83x110x155 | 3 | | | | SMCW6110 | 11kW | 19kW | 6,4kW | 11kW | 25A | 15,5A | 110x110x180 | 4 | | | | SMCW6150 | 15kW | 26kW | 8,6kW | 15kW | 30A | 22,5A | 110x141x180 | 5 | | | | SMCW6151 | 15kW | 26kW | 8,6kW | 15kW | 30A(AC53b) | 22,5A(AC53b) | Ext. bypass required | 83x110x74 | 1 | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | Common characteristics | Rang of voltage and network frequency | Control | Diagnostic output | Operating Temperature | Insulation | Max. section of wires | | | | Values given at 40°Cambient | 200-480VAC 40-65HZ | 10-24VDC or contact | 0-24V 1A AC/DC | -40 - + 100°C | 4kV | E=2,5mm2 S=10mm2 | | | | | | | | | | | | | | | | | | 4P | | | | | | | | | | | | | | The star assembly (Y) corresponds to in-line wired starter. The delta assembly (D) corresponds to the starter wired in the triangle coupling of the motor. Each channel is wired in series with a winding of the motor. | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | |
|