SPECIFICATION
Scanning Spécification
Wavelength Range Optical Bandwidth Digital Resolution Wavelength Accuracy Wavelength Reproducibility Absorbance Range Scan Speeds Baseline Flatness Second Order Filter Noise
Drift
Overlayed Scans Scan Trigger Number of Peak Scans Scan Storage Multiple Scans of a Peak Used with DataStream Software
190-700nm
4nm - constant
1nm
1nm
± 0.1nm
0.001 to 3A
Up to 1000nm/s - UV scan in 200ms ± 0.002A over most of range Fast automatic insertion at 370nm
< ±0.5 x 10-5 A, 230nm, 2 s T/C, using air test cell
< ±0.3 x 10-4 A/h, 230nm, at equilibrium using air test cell Up to 8 scans may be overlayed
Start of peak, set Abs value, point of inflection or at peak Up to 100 peaks for a single elution Up to 100 scans password protected Up to 8 scans of any peak
Data to PC, PC control, scan triggering, Lambda max. scans, peak purity and purity calculation, graphical presentation, overlay, normalisation, disk storage, library store and search, export, and many other functions.
Ordering
CE4300 Dynamic Absorbance Detector
Wavelength range 190-700nm, 4nm constant optical bandpass, ultra fast wavelength scan (on-the-fly) with auto peak triggering.
Variable wavelength monitoring, dual wavelength operation and programmable monitoring for up to 6 wavelengths.
Complete with instruction manual, power cable, signal cable and air test cell. Requires flowcell to be ordered.
CE4051
Column mounting panel with column cover.
CE4050
Column mounting panel with column cover and Rheodyne injection valve fitted with 20uL loop.
Flowcells
1200 07 70 1200 07 71 1200 07 72 1200 07 73 1200 07 74
8uL x 10mm pathlength
30uL x 10mm pathlength
4uL x 5mm pathlength
1mm pathlength preparative flowcell
12uL x 7mm pathlength
Variable Wavelength Détection Spécification
Wavelength Range Wavelength Accuracy Wavelength Reproducibility Absorbance Range Absorbance Linearity Optical Bandwidth Dual Wavelength Operation Wavelength Programming
Noise
Drift
Noise - Dual Wavelength Drift - Dual Wavelength
General Specification
Optical System
Monochromator
Straylight
Detectors
Lamp
Taper Beam Optics Self Test
Autozero Time Constant Wavelength Calibration Display
Fast Number Entry Event Marking Method Storage Automatic Power-Up/Off Outputs
Inputs
Size and Weight Power Requirements
190-700nm 1nm ± 0.1nm 0.001 to 3A
Better than 1% 0.001 - 2A 4nm - constant
Simultaneous measurement at 2 wavelengths and ratio
Measurements at up to 6 different wavelengths with a
time program and selectable sensitivity
± 0.5 x 10-5 A at 230nm, 2s T/C, using air test cell
±0.3 x 10-4 A/h at 230nm at equilibrium, using test cell
±3 x 10-5 A at 250/280nm
±3 x 10^ A/h at 250/280nm, constant temperature
Other flowcells available on request
Printers
Dot matrix printer with signal cable Colour inkjet printer with signal cable Laser printer with signal cable
CE4900
PowerStream software - provides PC workstation control of Cecil HPLC systems and data processing of chromatograms.
9000 20 00
DataStream Software - required for operation of the CE4300 in conjunction with a PC. No data processing of chromatograms.
Double Beam
Littrow with 1200 l/mm holographic grating
< 0.02% at 220nm and 340nm
Two Silicon Diodes
Deuterium lamp with elapsed time indicator
All energy collected to minimise RI effects
Automatic at switch-on; continuous monitoring of key
functions
By control panel or external trigger
0.1 second - 10 seconds, selectable
Automatic at switch-on using deuterium emission line.
Four-line display of parameters, menus, prompts,
wavelength, absorbance etc.
By use of special number keys
From keypad or by external trigger
For up to 30 methods, security protected
Pre-programmed to save warm up time
Two absorbance outputs, or absorbance and absorbance
ratio, parallel printer, data available to PC.
Event, autozero
365 x 290 x 140mm, 17kg
115V or 230V, 50/60Hz, 50VA
Chromatography System Manager
System Requirements
• Computer with Pentium class processor
• Pentium 200 MHz or better
• Microsoft Windows XP
• Microsoft Windows 2000
• 128 MB of RAM or more
• Hard-disk space required: 15 MB
• CD-ROM drive
• XGA or higher resolution monitor
• Monitor resolution 1024 x 768 or better
• Microsoft Mouse or compatible pointer
Cecil Instruments policy is one of continuous development. We therefore reserve the right to change spécification without notice.
CECIL INSTRUMENTS LIMITED MILTON TECHNICAL CENTRE CAMBRIDGE CB4 6AZ ENGLAND
ISO 9001:2000
TELEPHONE: 01223 420821 FAX: 01223 420475 CERTIFIED COMPANY
E-MAIL: info@cecilinstruments.com WEB SITE: www.cecilinstruments.com
12