SPECIFICA
Monochromator Optical Bandwidth Wavelength Range Wavelength Accuracy Wavelength Reproducibility Self Test and Calibration Straylight
Display Screen - LCD Display Scrolling Autozero
Photometric Ranges Photometric Accuracy Photometric Noise
Stability
Multi-Wavelength Analysis Assay Program
Curve Fitting and Editing
Cell and Wavelength Programming
Method Storage
Absorbance Ratioing
Peak Seek
Reaction Kinetics
Batch Sampling
Real Time Clock
Computer/printer interfaces
Sample Temperature
Size
Weight
Power Requirements
Littrow, 1200 lines/mm holographic grating 4nm - Aurius; 1.8nm Super Aurius 190-1000nm; 325-1000nm visible versions Better than ±1nm 0.1nm
Automatic at switch on
Typically less than 0.01% at 220 and 340nm
High resolution backlit with contrast control
Provides 6 screen widths for viewing plots etc.
Automatic by press button
Digital display of -0.3-3A, 0-200%T, 0-9999C
±0.005A or 1% whichever is greater
Less than ±0.00004A (500nm RMS)
Better than 0.001A/hour at constant temp.
2 and 3 wavelength methods
Enter multi-wavelength formula for automatic
computation and formatting of any assay
Linear, quadratic or cubic; up to 30 standards
Up to 8 cells and 10 wavelengths combined
Up to 30 methods stored in protected memory
260/280nm or any two selected wavelengths
Automatic search, baseline corrected
Tabulated results, reaction plots, reprocessing
100 samples, internal control, screen display
Timed and dated reports
Bi-directional serial RS232 and parallel ports
Displayed and set from keyboard
480 x 340 x 205mm
16.8kg Visible; 18.6kg UV; + 0.9kg with printer 110-250V, 50/60Hz; 120W/170W UV versions
HOGHftGHTS
BENEFITS
High Performance Scans Derivative Spectra Time Plots
Assay Formula Program DataStream - Fast Data to PC Display Scrolling - 6 Screens Wide
E-SEF Software Call-up
Integral Printer Versions Method Storage Cell and Wavelength Programs Kinetics, Single/Multi-cell Multi-Wavelength Assays UV Lamp 1500 Hour Guarantee Self Test and Calibration Compact - Only 48cm Wide
PERFORMANCE
Optical Bandwidth 1.8nm
Straylight 0.01%
Wavelength Precision 0.1nm
Stability ±0.001 A/hour
Accurate to 3A
Full Validation Procedures
Optical Bandwidth Wavelength Scanning and Range Wavelength Scale Expansion Scan Speed
Photometric Plotting Ranges
Baseline Flatness
Overlayed Spectra
Spectral Reprocessing
Dynamic Scan Recall Spectral Storage
Derivative Spectra
Multi-cell Kinetics
Band Quantification Time Course Plotting
1.8nm
1-4000nm/min; 190-1000nm
Selectable by keyboard entry 1-100nm/cm
Selectable by keyboard entry 1-4000nm/min
Keyboard entry of limits; or automatic
optimum
Better than ±0.002A (300nm/min) most of range
Up to 6 Spectra and derivatives with or without offsets
Spectra manipulated and replotted over any range
Instant, automatic recall of last 8 scans
Up to 100 spectra may be stored security
code protected
1st and 2nd derivatives
Up to 4 or 6 cells, with with plots and
reprocessing
Automatic band area and height correction Plots may be reprocessed and stored
Cecil Instruments policy is one of continuous development. We therefore reserve the right to change spécification without notice.
CECIL INSTRUMENTS LIMITED MILTON TECHNICAL CENTRE
CAMBRIDGE CB4 6AZ ENGLAND ISO 9000
TEL: 01223 420821 FAX: 01223 420475 CERT|F|ED COMPANY
E-MAIL: info@cecilinstruments.com WEBSITE: www.cecilinstruments.com